This study pioneers the use of minute-level CRRT machine pressure waveforms as a continuous signal for predicting mortality in critically ill patients with acute kidney injury, moving beyond traditional reliance on intermittent electronic health record data. By employing a transformer-based stacked ensemble that fuses these circuit-instability features with clinical variables, the model achieves superior prognostic performance while identifying specific hemodynamic markers like transmembrane pressure as key predictors. This work demonstrates how repurposing discarded sensor artifacts into high-fidelity risk signals can significantly enhance early detection capabilities in intensive care settings.
Sursă care acoperăarXiv
Ce este aceastaLectura unui model asupra articolului și a acoperirii conexe, scrisă pentru aiqbench. Nu sunt cuvintele publicației.

Rolling Day-Wise Mortality Prediction in Critically Ill Patients With AKI on CRRT Utilizing Machine Pressure Waveforms

arXiv3 min de cititArticolul și perspectiva sunt în engleză.

arXiv:2609.13524v1 Announce Type: cross Abstract: Critically ill patients with acute kidney injury (AKI) on continuous renal replacement therapy (CRRT) face high mortality, yet current risk assessment relies primarily on clinical parameters from electronic health records (EHR) and ignores minute-level circuit pressure waveforms generated by CRRT machines that track the extracorporeal circuit's interaction with the patient. Clinicians therefore cannot see deterioration as it develops. Risk is reassessed only when labs are drawn, while this continuous record is discarded because it is contaminated by shared-device records, non-physiological minutes, and sensor artifacts. To make the stream usable, we aligned machine records to charted therapy intervals to prevent cross-patient leakage, removed priming and downtime minutes, tuned denoising on a synthetic spike-injection benchmark, and masked unobserved intervals rather than imputing them. On this cleaned stream, we define a rolling day-wise task and a transformer-based stacked ensemble that late-fuses a window-reduced sequence transformer with classical models using circuit-instability features and clinical EHR variables. In a leak-safe benchmark on the multi-center CRRTnet cohort (976 patients, 4,585 treatment days), the machine-only model had the lowest standalone prognostic value (AUROC 0.625), followed by the EHR-only model (0.717). Integrating EHR and machine streams reached a one-day mortality AUROC of 0.766. SHAP attribution showed that circuit-instability descriptors raised the machine share of the top 15 combined-model features from 3 to 7 (20.0% to 46.7%), highlighting filter pressure, transmembrane pressure (TMP), and access-to-return difference (ARD). To our knowledge, this is the first patient-level mortality prediction incorporating CRRT machine data, turning a discarded bedside stream into a continuous risk signal.

Abstract:Critically ill patients with acute kidney injury (AKI) on continuous renal replacement therapy (CRRT) face high mortality, yet current risk assessment relies primarily on clinical parameters from electronic health records (EHR) and ignores minute-level circuit pressure waveforms generated by CRRT machines that track the extracorporeal circuit's interaction with the patient. Clinicians therefore cannot see deterioration as it develops. Risk is reassessed only when labs are drawn, while this continuous record is discarded because it is contaminated by shared-device records, non-physiological minutes, and sensor artifacts. To make the stream usable, we aligned machine records to charted therapy intervals to prevent cross-patient leakage, removed priming and downtime minutes, tuned denoising on a synthetic spike-injection benchmark, and masked unobserved intervals rather than imputing them. On this cleaned stream, we define a rolling day-wise task and a transformer-based stacked ensemble that late-fuses a window-reduced sequence transformer with classical models using circuit-instability features and clinical EHR variables. In a leak-safe benchmark on the multi-center CRRTnet cohort (976 patients, 4,585 treatment days), the machine-only model had the lowest standalone prognostic value (AUROC 0.625), followed by the EHR-only model (0.717). Integrating EHR and machine streams reached a one-day mortality AUROC of 0.766. SHAP attribution showed that circuit-instability descriptors raised the machine share of the top 15 combined-model features from 3 to 7 (20.0% to 46.7%), highlighting filter pressure, transmembrane pressure (TMP), and access-to-return difference (ARD). To our knowledge, this is the first patient-level mortality prediction incorporating CRRT machine data, turning a discarded bedside stream into a continuous risk signal.

Machine Learning (cs.LG); Artificial Intelligence (cs.AI)

arXiv:2609.13524 [cs.LG]

(or arXiv:2609.13524v1 [cs.LG] for this version)

https://doi.org/10.48550/arXiv.2609.13524 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Text integral sub licența deschisă a publicației · 349 cuvinte

Subiecte conexe