This research advances AI applications in energy systems by demonstrating how decoupled reinforcement learning architectures can maintain high robustness against measurement noise and grid-model mismatches in low-voltage distribution networks. By combining a random-forest pre-classifier with an actor-critic controller, the study provides critical insights into deploying machine learning for real-time congestion management where data is sparse or imperfect.
Sursă care acoperăarXiv
Ce este aceastaLectura unui model asupra articolului și a acoperirii conexe, scrisă pentru aiqbench. Nu sunt cuvintele publicației.

Robustness of Reinforcement Learning-Based Congestion Management in Low-Voltage Grids

arXiv2 min de cititArticolul și perspectiva sunt în engleză.

arXiv:2607.16004v1 Announce Type: cross Abstract: Increases in photovoltaic generation, charging of electric vehicles and heat-pump demand challenge operating limits in low-voltage distribution grids. This requires curative curtailment methods that can operate under sparse observability, noisy measurements, and imperfect grid models. Unlike prior end-to-end reinforcement-learning approaches for partially observable curtailment, this work decouples congestion detection and control by combining a random-forest violation pre-classifier with an actor-critic controller, and evaluates its robustness to measurement noise and grid-parameter mismatch. The framework is tested on a real low-voltage grid using synthetic future operating scenarios with low observability and controllability. With accurate grid parameters, the controller reduces total violation magnitude by 98.9%, and this performance remains nearly unchanged under the tested measurement-noise settings. Grid-model mismatch proves to be more challenging, but the controller still mitigates most violations under the tested mismatch assumptions.

Abstract:Increases in photovoltaic generation, charging of electric vehicles and heat-pump demand challenge operating limits in low-voltage distribution grids. This requires curative curtailment methods that can operate under sparse observability, noisy measurements, and imperfect grid models. Unlike prior end-to-end reinforcement-learning approaches for partially observable curtailment, this work decouples congestion detection and control by combining a random-forest violation pre-classifier with an actor-critic controller, and evaluates its robustness to measurement noise and grid-parameter mismatch. The framework is tested on a real low-voltage grid using synthetic future operating scenarios with low observability and controllability. With accurate grid parameters, the controller reduces total violation magnitude by 98.9%, and this performance remains nearly unchanged under the tested measurement-noise settings. Grid-model mismatch proves to be more challenging, but the controller still mitigates most violations under the tested mismatch assumptions.

6 pages, 5 figures. Accepted for publication at SEST 2026

Systems and Control (eess.SY); Artificial Intelligence (cs.AI)

arXiv:2607.16004 [eess.SY]

(or arXiv:2607.16004v1 [eess.SY] for this version)

https://doi.org/10.48550/arXiv.2607.16004 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Text integral sub licența deschisă a publicației · 240 cuvinte