Sari la conținut

Română · beta. Traducerea a fost făcută automat și este încă în curs de revizuire. Citește pagina în engleză

perspectiva aiqbenchCercetare AI

analiza aiqbench

This study enhances the WT-PSE framework for medical image segmentation by introducing domain-adaptive augmentations, a hybrid loss function, and curriculum-based weighting to improve robustness against scanner variations and edge noise. The proposed training-level modifications achieve a significant boost in Dice scores without altering the underlying architecture, offering a practical path for improving model generalization in multi-domain clinical settings.
Sursă care acoperăarXiv
Ce este aceastaLectura unui model asupra articolului și a acoperirii conexe, scrisă pentru aiqbench. Nu sunt cuvintele publicației.

ROBUST-WT: Robust Uncertainty-aware Segmentation Transform via Whitening and Training Enhancements

arXiv3 min de cititArticolul și perspectiva sunt în engleză.

arXiv:2606.03069v1 Announce Type: cross Abstract: Generalized segmentation of medical images prevents performance degradation when different imaging devices and clinical protocols are used across multiple domains. The Whitening Transform-based Probabilistic Shape Regularization Extractor (WT-PSE), published in IEEE Transactions on Medical Imaging in 2024, addresses this challenge by employing feature decorrelation and Wasserstein distance-based knowledge distillation to achieve robust cross-domain segmentation. This study systematically examines improvements to the WT-PSE learning framework. Four limitations in the original implementation are identified: limited training augmentations that fail to simulate real scanner variations, reliance on per-pixel binary cross-entropy loss that is sensitive to edge noise, the absence of a scheduled loss weighting strategy that may destabilize early training, and the lack of ablation switches for controlled scientific comparison. To address these issues, we propose four enhancements: (1) domain-adaptive augmentation including random erasing, gamma correction, and salt-and-pepper noise; (2) a hybrid BCE and Dice loss function for improved edge-aware segmentation under noisy conditions; (3) a curriculum-based Dice weight scheduling strategy; and (4) command-line control flags for systematic ablation studies. Experiments on the fundus optic disc segmentation benchmark demonstrate that the improved pipeline achieves a final epoch optic-disc Dice score of 0.956 and an ASD score of 13.31, outperforming the baseline epoch-5 Dice score of 0.939. These results indicate that training-level improvements can provide consistent performance gains without modifying the underlying WT-PSE architecture.

Abstract:Generalized segmentation of medical images prevents performance degradation when different imaging devices and clinical protocols are used across multiple domains. The Whitening Transform-based Probabilistic Shape Regularization Extractor (WT-PSE), published in IEEE Transactions on Medical Imaging in 2024, addresses this challenge by employing feature decorrelation and Wasserstein distance-based knowledge distillation to achieve robust cross-domain segmentation. This study systematically examines improvements to the WT-PSE learning framework. Four limitations in the original implementation are identified: limited training augmentations that fail to simulate real scanner variations, reliance on per-pixel binary cross-entropy loss that is sensitive to edge noise, the absence of a scheduled loss weighting strategy that may destabilize early training, and the lack of ablation switches for controlled scientific comparison. To address these issues, we propose four enhancements: (1) domain-adaptive augmentation including random erasing, gamma correction, and salt-and-pepper noise; (2) a hybrid BCE and Dice loss function for improved edge-aware segmentation under noisy conditions; (3) a curriculum-based Dice weight scheduling strategy; and (4) command-line control flags for systematic ablation studies. Experiments on the fundus optic disc segmentation benchmark demonstrate that the improved pipeline achieves a final epoch optic-disc Dice score of 0.956 and an ASD score of 13.31, outperforming the baseline epoch-5 Dice score of 0.939. These results indicate that training-level improvements can provide consistent performance gains without modifying the underlying WT-PSE architecture.

Computer Vision and Pattern Recognition (cs.CV); Artificial Intelligence (cs.AI); Machine Learning (cs.LG)

arXiv:2606.03069 [cs.CV]

(or arXiv:2606.03069v1 [cs.CV] for this version)

https://doi.org/10.48550/arXiv.2606.03069 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Text integral sub licența deschisă a publicației · 323 cuvinte

Subiecte conexe