Sari la conținut

Română · beta. Traducerea a fost făcută automat și este încă în curs de revizuire. Citește pagina în engleză

perspectiva aiqbenchCalcul cuantic

analiza aiqbench

This research introduces a refined metrology technique that mitigates systematic errors in Pound-Drever-Hall spectroscopy, directly enhancing the precision required for controlling superconducting qubits and other quantum systems. By optimizing phase combinations across interrogation tones, the method achieves robust frequency measurements in both optical and microwave regimes without relying on path-length stability. This advancement addresses a critical bottleneck in scaling quantum hardware where high-fidelity readout depends on minimizing technical noise sources.
Sursă care acoperăarXiv
Ce este aceastaLectura unui model asupra articolului și a acoperirii conexe, scrisă pentru aiqbench. Nu sunt cuvintele publicației.

Robust cavity metrology beyond the limits of Pound-Drever-Hall

arXiv2 min de cititArticolul și perspectiva sunt în engleză.

arXiv:2608.21512v1 Announce Type: new Abstract: Precise measurement of the resonance frequencies of microwave and optical cavities is a foundational capability across quantum technologies. One of the highest-performance methods currently available is Pound-Drever-Hall (PDH) spectroscopy, which relies on a three-tone interrogation and eliminates sensitivity to path-length fluctuations. However, PDH is known to suffer from systematic offsets due to residual amplitude modulation and demodulation-phase errors. Here we leverage an optimal linear combination of the phases of the three interrogation tones to implement a method for robust cavity metrology which eliminates significant systematic-error sensitivities of PDH. We experimentally demonstrate robust cavity measurements in both the optical and microwave frequency regime, showing insensitivity to sideband imbalance and demodulation phase, as well as demonstrating single-shot readout of a cavity-coupled superconducting qubit.

Abstract:Precise measurement of the resonance frequencies of microwave and optical cavities is a foundational capability across quantum technologies. One of the highest-performance methods currently available is Pound-Drever-Hall (PDH) spectroscopy, which relies on a three-tone interrogation and eliminates sensitivity to path-length fluctuations. However, PDH is known to suffer from systematic offsets due to residual amplitude modulation and demodulation-phase errors. Here we leverage an optimal linear combination of the phases of the three interrogation tones to implement a method for robust cavity metrology which eliminates significant systematic-error sensitivities of PDH. We experimentally demonstrate robust cavity measurements in both the optical and microwave frequency regime, showing insensitivity to sideband imbalance and demodulation phase, as well as demonstrating single-shot readout of a cavity-coupled superconducting qubit.

arXiv:2608.21512 [quant-ph]

(or arXiv:2608.21512v1 [quant-ph] for this version)

https://doi.org/10.48550/arXiv.2608.21512 Focus to learn more arXiv-issued DOI via DataCite

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Text integral sub licența deschisă a publicației · 210 cuvinte

Subiecte conexe