analiza aiqbench
This research establishes a critical framework for validating uncertainty estimation in clinical vision-language models by aligning correctness criteria with human judgment rather than relying on flawed exact matching. The study reveals that the choice of evaluation metric can drastically alter error-detection performance and even reverse the ranking of different uncertainty methods, highlighting a significant risk in current deployment strategies. For safety-critical AI applications, these findings underscore the necessity of rigorously validating how model outputs are defined as "correct" before assessing their reliability.
Rethinking Correctness for Uncertainty Estimation in Clinical Prediction with Vision-Language Models
arXiv:2609.15180v1 Announce Type: new Abstract: Vision-language models are increasingly explored for clinical prediction from electronic health records and medical images, where identifying unreliable predictions is important for safe deployment. Uncertainty estimation (UE) enables detecting such predictions, but its evaluation depends on a correctness criterion that determines whether each model output is correct. If this criterion disagrees with human judgement or distorts downstream UE performance, conclusions about model reliability can be misleading. We introduce a two-axis framework that evaluates correctness criteria by their agreement with human judgements and fidelity to human-referenced UE performance. We assess eight criteria across three clinical prediction tasks and three models using 450 predictions annotated by two reviewers. Across the audited tasks, canonical exact matching (EM) achieved the highest observed human agreement and lowest UE distortion, while the BERT-based matching (BEM) and LLM-judge also showed strong human agreement. Across four UE methods and 23,254 clinical predictions, criterion choice changed error-detection AUROC by up to 0.146 and reversed the relative ranking of UE methods. The LLM-judge also selectively accepted invalid or uncertain outputs, accepting 16 of 30 such human-identified errors. These results demonstrate that correctness assessment is an integral component of clinical UE evaluation and should be validated before UE methods are compared.
Abstract:Vision-language models are increasingly explored for clinical prediction from electronic health records and medical images, where identifying unreliable predictions is important for safe deployment. Uncertainty estimation (UE) enables detecting such predictions, but its evaluation depends on a correctness criterion that determines whether each model output is correct. If this criterion disagrees with human judgement or distorts downstream UE performance, conclusions about model reliability can be misleading. We introduce a two-axis framework that evaluates correctness criteria by their agreement with human judgements and fidelity to human-referenced UE performance. We assess eight criteria across three clinical prediction tasks and three models using 450 predictions annotated by two reviewers. Across the audited tasks, canonical exact matching (EM) achieved the highest observed human agreement and lowest UE distortion, while the BERT-based matching (BEM) and LLM-judge also showed strong human agreement. Across four UE methods and 23,254 clinical predictions, criterion choice changed error-detection AUROC by up to 0.146 and reversed the relative ranking of UE methods. The LLM-judge also selectively accepted invalid or uncertain outputs, accepting 16 of 30 such human-identified errors. These results demonstrate that correctness assessment is an integral component of clinical UE evaluation and should be validated before UE methods are compared.
Machine Learning (cs.LG)
arXiv:2609.15180 [cs.LG]
(or arXiv:2609.15180v1 [cs.LG] for this version)
https://doi.org/10.48550/arXiv.2609.15180 Focus to learn more arXiv-issued DOI via DataCite (pending registration)
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.
Text integral sub licența deschisă a publicației · 294 cuvinte
Subiecte conexe
Uncertainty Is Not a Safety Net for Clinical VQA, but Can It Anticipate Model Failure?
arXiv · 4 sept. 2026
Uncertainty Is Not a Safety Net for Clinical VQA, but Can It Anticipate Model Failure?
arXiv · 17 iun. 2026
Monte Carlo Dropout Uncertainty and Entropy-Thresholded Selective Prediction for Architecture-Agnostic Brain Tumor MRI Triage
arXiv · 21 iul. 2026

34 Amazon Research Awards Build on Trainium recipients announced
Amazon Science · 5 aug. 2026