Sari la conținut

Română · beta. Traducerea a fost făcută automat și este încă în curs de revizuire. Citește pagina în engleză

perspectiva aiqbenchMachine learning

analiza aiqbench

ReCoGen introduces a novel two-stage framework that effectively handles irregular missingness in multimodal physiological time series by decoupling condition representation from signal generation. By utilizing masked autoencoders for dynamic signals and flow-matching generators fused with static covariates, the method achieves superior downstream utility across major clinical benchmarks like MIMIC-IV without relying on invasive data as a performance ceiling. This advancement offers a practical pathway to reduce patient burden in continuous monitoring by synthesizing critical but unavailable signals from routine measurements.
Sursă care acoperăarXiv
Ce este aceastaLectura unui model asupra articolului și a acoperirii conexe, scrisă pentru aiqbench. Nu sunt cuvintele publicației.

Represent, Then Generate: Multimodal-Conditioned Time-Series Generation under Irregular Missingness

arXiv3 min de cititArticolul și perspectiva sunt în engleză.

arXiv:2608.12592v2 Announce Type: replace Abstract: Continuous physiological time series underpin modern clinical monitoring, yet many of the most informative signals are invasive, expensive, or simply unavailable for a given patient. Conditional generation offers a remedy: an absent signal can be synthesized from co-recorded signals and routine clinical variables. Existing generators, however, are built around a single conditioning modality and degrade when forced to handle the heterogeneous, irregularly missing mix of time-variant signals and static covariates seen in practice. We propose ReCoGen (Represent Conditions, then Generate), a two-stage framework that decouples multimodal condition representation from target generation. Stage I trains one masked autoencoder per modality, distilling each time-variant condition into a compact and missingness-tolerant token sequence. Stage II trains a flow-matching generator that fuses these tokens with static conditions to synthesize the target signal. Across three physiological benchmarks, including continuous glucose monitoring on AI-READI and arterial blood pressure generation on MIMIC-III and MIMIC-IV, ReCoGen attains the best downstream utility on all sixteen (dataset, task, metric) settings, surpassing six representative conditional generators; on thirteen of them its utility also reaches or exceeds the utility measured on the real signal, a reference we read as an approximate anchor rather than a ceiling. Ablations trace the gains to the conditioning path: learnable cross-attention over the frozen per-modality encoders, and a dual token-plus-AdaLN route for the static conditions. ReCoGen thus turns routinely collected signals into informative surrogates for invasive or unavailable ones, a step toward less invasive, lower-cost continuous clinical monitoring.

Abstract:Continuous physiological time series underpin modern clinical monitoring, yet many of the most informative signals are invasive, expensive, or simply unavailable for a given patient. Conditional generation offers a remedy: an absent signal can be synthesized from co-recorded signals and routine clinical variables. Existing generators, however, are built around a single conditioning modality and degrade when forced to handle the heterogeneous, irregularly missing mix of time-variant signals and static covariates seen in practice. We propose ReCoGen (Represent Conditions, then Generate), a two-stage framework that decouples multimodal condition representation from target generation. Stage I trains one masked autoencoder per modality, distilling each time-variant condition into a compact and missingness-tolerant token sequence. Stage II trains a flow-matching generator that fuses these tokens with static conditions to synthesize the target signal. Across three physiological benchmarks, including continuous glucose monitoring on AI-READI and arterial blood pressure generation on MIMIC-III and MIMIC-IV, ReCoGen attains the best downstream utility on all sixteen (dataset, task, metric) settings, surpassing six representative conditional generators; on thirteen of them its utility also reaches or exceeds the utility measured on the real signal, a reference we read as an approximate anchor rather than a ceiling. Ablations trace the gains to the conditioning path: learnable cross-attention over the frozen per-modality encoders, and a dual token-plus-AdaLN route for the static conditions. ReCoGen thus turns routinely collected signals into informative surrogates for invasive or unavailable ones, a step toward less invasive, lower-cost continuous clinical monitoring.

Machine Learning (cs.LG)

arXiv:2608.12592 [cs.LG]

(or arXiv:2608.12592v2 [cs.LG] for this version)

https://doi.org/10.48550/arXiv.2608.12592 Focus to learn more arXiv-issued DOI via DataCite

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Text integral sub licența deschisă a publicației · 333 cuvinte

Subiecte conexe