analiza aiqbench
This research introduces PulseFlow, a generative framework using invertible latent transport to synthesize atrial fibrillation signals from normal source data, addressing the scarcity of labeled medical recordings for AI models. By explicitly modeling the transformation between cardiac rhythms while preserving source information, the method improves classification accuracy in low-data clinical settings. The work advances machine learning applications in healthcare by demonstrating effective counterfactual generation for continuous cardiovascular monitoring.
Pulseflow: PPG Counterfactual Generation Via Latent Transport
arXiv:2609.33501v1 Announce Type: new Abstract: Photoplethysmography (PPG) has become an important modality for continuous cardiovascular monitoring, including atrial fibrillation (AF) detection. However, labeled AF recordings remain limited in many clinical settings, making model adaptation difficult when only limited target data are available. Generative modeling offers a natural way to alleviate this scarcity by synthesizing additional AF signals. Existing approaches, however, mainly generate samples that match the target condition without explicitly modeling how an observed source recording should be transformed, making it difficult to leverage abundant source recordings from a specific population or cohort for targeted augmentation. We introduce PulseFlow, a source-conditioned counterfactual generation framework that combines conditional representation learning with invertible latent transport to edit cardiac rhythm while retaining information from the source. Experiments across two clinical cohorts demonstrate effective rhythm transformation, measurable source correspondence, and improved AF classification under limited labels.
Abstract:Photoplethysmography (PPG) has become an important modality for continuous cardiovascular monitoring, including atrial fibrillation (AF) detection. However, labeled AF recordings remain limited in many clinical settings, making model adaptation difficult when only limited target data are available. Generative modeling offers a natural way to alleviate this scarcity by synthesizing additional AF signals. Existing approaches, however, mainly generate samples that match the target condition without explicitly modeling how an observed source recording should be transformed, making it difficult to leverage abundant source recordings from a specific population or cohort for targeted augmentation. We introduce PulseFlow, a source-conditioned counterfactual generation framework that combines conditional representation learning with invertible latent transport to edit cardiac rhythm while retaining information from the source. Experiments across two clinical cohorts demonstrate effective rhythm transformation, measurable source correspondence, and improved AF classification under limited labels.
Machine Learning (cs.LG)
arXiv:2609.33501 [cs.LG]
(or arXiv:2609.33501v1 [cs.LG] for this version)
https://doi.org/10.48550/arXiv.2609.33501 Focus to learn more arXiv-issued DOI via DataCite (pending registration)
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.
Text integral sub licența deschisă a publicației · 231 cuvinte
Subiecte conexe
J++ Lens: Jacobian Filtering Enables More Faithful Workspace Lenses
LessWrong · 8 oct. 2026

Runway’s WorldPrompt and the Engineering of Real-Time Worlds
Latent Space · 25 sept. 2026
Self-Consistent Generative Paths via Admissible Random Variational Transport
arXiv · 9 iun. 2026
GLASS: Global Latent Aggregation with Slot-based Set Decoding for Scalable All-Atom Crystal Generation
arXiv · 30 sept. 2026