analiza aiqbench
This research addresses critical bottlenecks in medical AI by establishing a standardized benchmark for X-ray report generation on the newly released CheXpert Plus dataset. The authors introduce MambaXray-PRB, a framework leveraging multi-stage pre-training and Chain-of-Thought reasoning to improve performance and interpretability over generic large models. By providing baseline implementations and evaluation metrics, this work facilitates fair comparison and accelerates progress in domain-specific radiology applications.
Pre-training, Reasoning, Benchmarking: X-ray Report Generation on CheXpert Plus Dataset
arXiv:2610.08813v1 Announce Type: cross Abstract: X-ray image-based Radiology Report Generation (RRG) constitutes a critical research direction within medical artificial intelligence, with great potential to alleviate clinicians' diagnostic workload and shorten patient waiting periods. Despite substantial advances over recent years, the field faces evident bottlenecks stemming from insufficient standardized benchmarks and inadequate domain adaptation of generic large models. Notably, the newly released CheXpert Plus dataset is provided without accompanying baseline implementations and evaluation results, which impedes standardized training, quantitative evaluation and fair comparison among follow-up algorithms. To mitigate this limitation, we establish a comprehensive benchmark encompassing prevailing X-ray report generation models and Large Language Models on CheXpert Plus. This benchmark delivers a reliable comparative foundation for upcoming methods and enables researchers to rapidly identify state-of-the-art approaches within this domain. Beyond benchmark construction, we rethink X-ray RRG under the paradigm of large models and propose a novel framework termed MambaXray-PRB. Our framework improves report generation performance and enhances model interpretability via multi-stage large-model pre-training and multi-modal Chain-of-Thought reasoning. The pipeline consists of three successive phases: self-supervised auto-regressive modeling, X-ray-report contrastive learning, and post-training optimization for reasoning and report generation. Extensive experiments on IU X-ray, MIMIC-CXR, and CheXpert Plus datasets validate the effectiveness of MambaXray-PRB for radiology report generation. The source code of this paper is available on https://github.com/Event-AHU/Medical_Image_Analysis
Abstract:X-ray image-based Radiology Report Generation (RRG) constitutes a critical research direction within medical artificial intelligence, with great potential to alleviate clinicians' diagnostic workload and shorten patient waiting periods. Despite substantial advances over recent years, the field faces evident bottlenecks stemming from insufficient standardized benchmarks and inadequate domain adaptation of generic large models. Notably, the newly released CheXpert Plus dataset is provided without accompanying baseline implementations and evaluation results, which impedes standardized training, quantitative evaluation and fair comparison among follow-up algorithms. To mitigate this limitation, we establish a comprehensive benchmark encompassing prevailing X-ray report generation models and Large Language Models on CheXpert Plus. This benchmark delivers a reliable comparative foundation for upcoming methods and enables researchers to rapidly identify state-of-the-art approaches within this domain. Beyond benchmark construction, we rethink X-ray RRG under the paradigm of large models and propose a novel framework termed MambaXray-PRB. Our framework improves report generation performance and enhances model interpretability via multi-stage large-model pre-training and multi-modal Chain-of-Thought reasoning. The pipeline consists of three successive phases: self-supervised auto-regressive modeling, X-ray-report contrastive learning, and post-training optimization for reasoning and report generation. Extensive experiments on IU X-ray, MIMIC-CXR, and CheXpert Plus datasets validate the effectiveness of MambaXray-PRB for radiology report generation. The source code of this paper is available on this https URL
Computer Vision and Pattern Recognition (cs.CV); Artificial Intelligence (cs.AI)
arXiv:2610.08813 [cs.CV]
(or arXiv:2610.08813v1 [cs.CV] for this version)
https://doi.org/10.48550/arXiv.2610.08813 Focus to learn more arXiv-issued DOI via DataCite
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.
Text integral sub licența deschisă a publicației · 311 cuvinte
Subiecte conexe

[AINews] Opus 5.5 is good at explainer videos
Latent Space · 29 sept. 2026

[AINews] The Future of Latent Space
Latent Space · 25 sept. 2026

Introducing CARE-X: Towards Clinically Useful Radiology VLMs with Auxiliary Supervision, Reward-Aligned Learning, and Tool-Augmented Measurement
Microsoft Research · 11 aug. 2026

[AINews] DeepSeek v4.1-Flash: 763B-P8B-D16B novel causal Encoder–Decoder architecture with vision marks the Return of the Whale
Latent Space · 12 sept. 2026