Sari la conținut

Română · beta. Traducerea a fost făcută automat și este încă în curs de revizuire. Citește pagina în engleză

perspectiva aiqbenchProduse AI

analiza aiqbench

This research presents a hybrid tactile sensor that combines electrical impedance tomography with pneumatic pressure layers to significantly improve force estimation accuracy in robotic skins. By leveraging the complementary strengths of both sensing modalities, the system reduces root-mean-square error by up to 60% while avoiding the need for heavy machine-learning pipelines or large datasets. This approach offers a practical, scalable solution for building robust, large-area contact sensors essential for advanced robotics applications.
Sursă care acoperăarXiv
Ce este aceastaLectura unui model asupra articolului și a acoperirii conexe, scrisă pentru aiqbench. Nu sunt cuvintele publicației.

Pneumatic-Tomographic Tactile Skin for Multicontact Localization and Force Estimation

arXiv3 min de cititArticolul și perspectiva sunt în engleză.

arXiv:2503.13036v3 Announce Type: replace Abstract: Tactile skins based on electrical impedance tomography (EIT) enable large-area contact localization with few electrodes, but suffer from nonuniform sensitivity that limits force estimation accuracy. This work introduces a dual-channel tactile skin that integrates an EIT layer with a pneumatic pressure layer and a calibration framework that leverages their complementary strengths. The EIT layer provides robust multicontact localization, while the pneumatic pressure layer supplies a stable scalar measurement that serves as contact force estimation. A location-aware correction method is introduced, learning smooth spatial gain and offset fields from a single-session calibration, enabling spatially consistent multicontact force estimation. With location-aware correction, the proposed system achieves a single-contact force estimation root-mean-square error (RMSE) of 0.59 N across 10-25-mm indenters, representing a 35%-60% reduction over EIT-only approaches (1.45-1.48 N). In multicontact experiments, the per-contact RMSE is reduced by 39.6% compared to the uncorrected pneumatic baseline. The proposed system achieves accurate force estimation across diverse contact configurations, generalizes to varying indenter sizes, and preserves EIT's inherent advantages in multicontact localization. By letting the pneumatic pressure layer handle the force estimation and using the EIT layer to determine where each contact occurs, the method avoids the need for large datasets, complicated calibration setups, and heavy machine-learning pipelines often required by previous EIT-only approaches. This dual-channel design provides a practical, scalable, and easy-to-calibrate solution for building large-area robotic skins.

Abstract:Tactile skins based on electrical impedance tomography (EIT) enable large-area contact localization with few electrodes, but suffer from nonuniform sensitivity that limits force estimation accuracy. This work introduces a dual-channel tactile skin that integrates an EIT layer with a pneumatic pressure layer and a calibration framework that leverages their complementary strengths. The EIT layer provides robust multicontact localization, while the pneumatic pressure layer supplies a stable scalar measurement that serves as contact force estimation. A location-aware correction method is introduced, learning smooth spatial gain and offset fields from a single-session calibration, enabling spatially consistent multicontact force estimation. With location-aware correction, the proposed system achieves a single-contact force estimation root-mean-square error (RMSE) of 0.59 N across 10-25-mm indenters, representing a 35%-60% reduction over EIT-only approaches (1.45-1.48 N). In multicontact experiments, the per-contact RMSE is reduced by 39.6% compared to the uncorrected pneumatic baseline. The proposed system achieves accurate force estimation across diverse contact configurations, generalizes to varying indenter sizes, and preserves EIT's inherent advantages in multicontact localization. By letting the pneumatic pressure layer handle the force estimation and using the EIT layer to determine where each contact occurs, the method avoids the need for large datasets, complicated calibration setups, and heavy machine-learning pipelines often required by previous EIT-only approaches. This dual-channel design provides a practical, scalable, and easy-to-calibrate solution for building large-area robotic skins.

Robotics (cs.RO); Signal Processing (eess.SP)

I.2.9; I.4.5; I.4.8

arXiv:2503.13036 [cs.RO]

(or arXiv:2503.13036v3 [cs.RO] for this version)

Chen, H., Kubik, J., Himmel, B., Hoffmann, M. and Lee, H. (2026), 'Pneumatic-Tomographic Tactile Skin for Multicontact Localization and Force Estimation', IEEE Sensors 26(16), 23655 - 23665

https://doi.org/10.1109/JSEN.2026.3704916 DOI(s) linking to related resources

From: Matej Hoffmann Ph.D. [view email] [v1] Mon, 17 Mar 2025 10:41:13 UTC (1,451 KB) [v2] Thu, 18 Dec 2025 18:54:47 UTC (1,099 KB) [v3] Thu, 27 Aug 2026 08:55:40 UTC (1,312 KB)

Text integral sub licența deschisă a publicației · 305 cuvinte

Subiecte conexe