This study applies physics-informed self-supervised learning to automate the calibration of particle detectors, eliminating the need for dedicated reference runs or labeled data. By jointly optimizing wire gains and interaction positions through geometry-based constraints, the method enables continuous self-calibration that adapts to detector aging and changing conditions. This represents a significant advancement in autonomous instrumentation where machine learning directly enhances the reliability of high-energy physics measurements.
Sursă care acoperăarXiv
Ce este aceastaLectura unui model asupra articolului și a acoperirii conexe, scrisă pentru aiqbench. Nu sunt cuvintele publicației.

Physics-Informed Self-Supervised Learning for Joint Wire Calibration and Interaction Position Reconstruction in Multi-Wire Parallel Plate Avalanche Counters

arXiv3 min de cititArticolul și perspectiva sunt în engleză.

arXiv:2609.28604v1 Announce Type: new Abstract: Scientific instruments require accurate calibration to convert detector signals into reliable physical observables. Conventional calibration procedures typically rely on dedicated calibration measurements, analytical response models or labelled reference data, limiting their ability to adapt to changing operating conditions and detector aging. We present a physics-informed self-supervised learning framework that jointly performs wire calibration and interaction position reconstruction in Multi-Wire Parallel Plate Avalanche Counters (MWPPACs) without requiring labelled position measurements or dedicated calibration runs. The method formulates detector calibration as a latent optimization problem in which global wire gains and event-wise interaction positions are estimated simultaneously using supervision derived exclusively from detector geometry and charge-energy consistency constraints. A detector-independent neural network reconstructs sub-wire interaction positions from local charge distributions, eliminating the need to assume analytical induction profiles by learning the detector response directly from experimental data. The end-to-end differentiable framework enables continuous detector self-calibration while improving the uniformity and accuracy of position reconstruction. Experimental evaluation on the entrance MWPPAC tracking detectors of the VAMOS++ magnetic spectrometer demonstrates stable convergence, improved spatial homogeneity and enhanced position resolution. Beyond the detector studied, the method establishes a general framework for physics-informed self-supervised calibration of scientific instruments and is a step toward autonomous intelligent instrumentation capable of continuous adaptation during operation. In this paradigm, detector calibration is no longer a prerequisite for an experiment but an integral part of the measurement process itself.

Abstract:Scientific instruments require accurate calibration to convert detector signals into reliable physical observables. Conventional calibration procedures typically rely on dedicated calibration measurements, analytical response models or labelled reference data, limiting their ability to adapt to changing operating conditions and detector aging. We present a physics-informed self-supervised learning framework that jointly performs wire calibration and interaction position reconstruction in Multi-Wire Parallel Plate Avalanche Counters (MWPPACs) without requiring labelled position measurements or dedicated calibration runs. The method formulates detector calibration as a latent optimization problem in which global wire gains and event-wise interaction positions are estimated simultaneously using supervision derived exclusively from detector geometry and charge-energy consistency constraints. A detector-independent neural network reconstructs sub-wire interaction positions from local charge distributions, eliminating the need to assume analytical induction profiles by learning the detector response directly from experimental data. The end-to-end differentiable framework enables continuous detector self-calibration while improving the uniformity and accuracy of position reconstruction. Experimental evaluation on the entrance MWPPAC tracking detectors of the VAMOS++ magnetic spectrometer demonstrates stable convergence, improved spatial homogeneity and enhanced position resolution. Beyond the detector studied, the method establishes a general framework for physics-informed self-supervised calibration of scientific instruments and is a step toward autonomous intelligent instrumentation capable of continuous adaptation during operation. In this paradigm, detector calibration is no longer a prerequisite for an experiment but an integral part of the measurement process itself.

Machine Learning (cs.LG); Nuclear Experiment (nucl-ex); Instrumentation and Detectors (physics.ins-det)

arXiv:2609.28604 [cs.LG]

(or arXiv:2609.28604v1 [cs.LG] for this version)

https://doi.org/10.48550/arXiv.2609.28604 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Text integral sub licența deschisă a publicației · 329 cuvinte

Subiecte conexe