Sari la conținut

Română · beta. Traducerea a fost făcută automat și este încă în curs de revizuire. Citește pagina în engleză

perspectiva aiqbenchComunicații cuantice

analiza aiqbench

This research establishes a theoretical framework demonstrating that spectrally multimode SU(1,1) interferometers can be modeled as parallel single-mode systems within the Schmidt basis to optimize phase sensitivity. By optimizing waveguide designs and signal spectra, the study provides practical methods to mitigate performance degradation caused by resource redistribution or coherence penalties in quantum-enhanced sensing applications.
Sursă care acoperăarXiv
Ce este aceastaLectura unui model asupra articolului și a acoperirii conexe, scrisă pentru aiqbench. Nu sunt cuvintele publicației.

Phase Sensitivity of Spectrally Multimode SU(1,1) Interferometers with Waveguide based Optical Parametric Amplifier

arXiv3 min de cititArticolul și perspectiva sunt în engleză.

arXiv:2607.29469v1 Announce Type: new Abstract: We present a comprehensive framework for evaluating the phase sensitivity of spectrally multimode SU(1,1) interferometers probed with a coherent-vacuum input, under both number and homodyne detections. The optical parametric amplifiers (OPAs) are simulated using a periodically polled thin-film lithium niobate waveguide. The theoretical model incorporates the intrinsic multimode spectral nature of waveguide-based OPAs. Under the assumptions of identical OPAs and Schmidt-mode-independent phase shifts, we have shown that the multimode SU(1,1) interferometer is equivalent to a collection of independent single-mode interferometers in the Schmidt basis that operate in parallel, each associated with a Schmidt mode of the parametric process. We further present an optimized waveguide design based on asymmetric group-velocity matching to realize a practical OPA with nearly factorizable joint spectral amplitude (JSA). The Schmidt coefficients extracted from the numerically simulated JSA are incorporated into the theoretical model to evaluate the phase sensitivity. The results show that the sensitivity under a multimode condition depends strongly on the measurement scheme. For number detection, the degradation in sensitivity arises from the redistribution of the available nonlinear resource among the Schmidt modes, whereas homodyne detection exhibits an additional coherence penalty that can be substantially reduced by optimally shaping the local oscillator. Moreover, we show that the performance degradation can be to a large extent mitigated by optimizing the spectrum of the injected signal coherent state and, in the case of homodyne detection, the spectrum of the local oscillator. Altogether, this work provides a unified theoretical and numerical framework for analyzing and optimizing realistic multimode SU(1,1) interferometers with waveguide-based OPAs for quantum-enhanced sensing applications.

Abstract:We present a comprehensive framework for evaluating the phase sensitivity of spectrally multimode SU(1,1) interferometers probed with a coherent-vacuum input, under both number and homodyne detections. The optical parametric amplifiers (OPAs) are simulated using a periodically polled thin-film lithium niobate waveguide. The theoretical model incorporates the intrinsic multimode spectral nature of waveguide-based OPAs. Under the assumptions of identical OPAs and Schmidt-mode-independent phase shifts, we have shown that the multimode SU(1,1) interferometer is equivalent to a collection of independent single-mode interferometers in the Schmidt basis that operate in parallel, each associated with a Schmidt mode of the parametric process. We further present an optimized waveguide design based on asymmetric group-velocity matching to realize a practical OPA with nearly factorizable joint spectral amplitude (JSA). The Schmidt coefficients extracted from the numerically simulated JSA are incorporated into the theoretical model to evaluate the phase sensitivity. The results show that the sensitivity under a multimode condition depends strongly on the measurement scheme. For number detection, the degradation in sensitivity arises from the redistribution of the available nonlinear resource among the Schmidt modes, whereas homodyne detection exhibits an additional coherence penalty that can be substantially reduced by optimally shaping the local oscillator. Moreover, we show that the performance degradation can be to a large extent mitigated by optimizing the spectrum of the injected signal coherent state and, in the case of homodyne detection, the spectrum of the local oscillator. Altogether, this work provides a unified theoretical and numerical framework for analyzing and optimizing realistic multimode SU(1,1) interferometers with waveguide-based OPAs for quantum-enhanced sensing applications.

arXiv:2607.29469 [quant-ph]

(or arXiv:2607.29469v1 [quant-ph] for this version)

https://doi.org/10.48550/arXiv.2607.29469 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Text integral sub licența deschisă a publicației · 350 cuvinte

Subiecte conexe