analiza aiqbench
PHASE introduces a physiology-guided foundation model for intracranial EEG that explicitly incorporates measurable physiological characteristics as learning targets, addressing limitations in current models that rely solely on implicit reconstruction. By pretraining on heterogeneous data across multiple clinical sites, the model achieves superior generalization and performance on diverse tasks like seizure detection without requiring local labels. This approach sets a new state of the art by bridging the gap between raw signal analysis and downstream clinical applications through explicit physiological supervision.
PHASE: A Physiology-Guided Hierarchical Foundation Model for Intracranial EEG
arXiv:2609.36087v1 Announce Type: cross Abstract: Clinicians and neuroscientists have long analyzed intracranial electroencephalography (iEEG) through directly measurable physiological characteristics, which carry much of the information that downstream tasks depend on. Recent iEEG foundation models learn by reconstructing or predicting their inputs, which leaves the retention of these characteristics implicit. They are also evaluated mainly on cognitive decoding and a narrow clinical task, i.e., seizure detection. On a broad, clinically relevant benchmark such as Omni-iEEG, they remain below task-specific models when used frozen. We introduce PHASE, a physiology-guided foundation model that makes these characteristics explicit learning targets, pairing them with masked latent prediction in a temporal stage (PHASE-T) within each channel and a spatiotemporal stage (PHASE-ST) across synchronized channels. PHASE is pretrained on heterogeneous recordings from 222 participants at nine clinical sites. On all five Omni-iEEG clinical tasks, frozen PHASE-T outperforms every evaluated foundation model by up to 31\%, and fine-tuned PHASE-T surpasses the task-specific models, setting a new state of the art. PHASE-T benefits from physiological supervision, outperforming variants trained with latent prediction alone or auxiliary waveform reconstruction on every task in matched ablations. PHASE-T generalizes to unseen institutions, outperforming the compared models with few or no local labels. PHASE-ST further improves seizure-onset-zone identification over PHASE-T and, when frozen, decodes sound volume and pitch on BrainTreebank better than published models. Beyond task performance, PHASE learns to encapsulate the physiological characteristics clinicians recognize, from seizure onset and its propagation to anatomical region identity, even though its pretraining contains no ictal recordings or anatomical labels.
Authors:Yipeng Zhang, Chenda Duan, Yuanyi Ding, Tianyi Wang, Atsuro Daida, Masaki Izumi, Yuta Tanoue, Naoto Kuroda, Shaun A. Hussain, Nishant Sinha, Eishi Asano.Hiroki Nariai, Vwani Roychowdhury
Abstract:Clinicians and neuroscientists have long analyzed intracranial electroencephalography (iEEG) through directly measurable physiological characteristics, which carry much of the information that downstream tasks depend on. Recent iEEG foundation models learn by reconstructing or predicting their inputs, which leaves the retention of these characteristics implicit. They are also evaluated mainly on cognitive decoding and a narrow clinical task, i.e., seizure detection. On a broad, clinically relevant benchmark such as Omni-iEEG, they remain below task-specific models when used frozen. We introduce PHASE, a physiology-guided foundation model that makes these characteristics explicit learning targets, pairing them with masked latent prediction in a temporal stage (PHASE-T) within each channel and a spatiotemporal stage (PHASE-ST) across synchronized channels. PHASE is pretrained on heterogeneous recordings from 222 participants at nine clinical sites. On all five Omni-iEEG clinical tasks, frozen PHASE-T outperforms every evaluated foundation model by up to 31\%, and fine-tuned PHASE-T surpasses the task-specific models, setting a new state of the art. PHASE-T benefits from physiological supervision, outperforming variants trained with latent prediction alone or auxiliary waveform reconstruction on every task in matched ablations. PHASE-T generalizes to unseen institutions, outperforming the compared models with few or no local labels. PHASE-ST further improves seizure-onset-zone identification over PHASE-T and, when frozen, decodes sound volume and pitch on BrainTreebank better than published models. Beyond task performance, PHASE learns to encapsulate the physiological characteristics clinicians recognize, from seizure onset and its propagation to anatomical region identity, even though its pretraining contains no ictal recordings or anatomical labels.
Machine Learning (cs.LG); Artificial Intelligence (cs.AI)
arXiv:2609.36087 [cs.LG]
(or arXiv:2609.36087v1 [cs.LG] for this version)
https://doi.org/10.48550/arXiv.2609.36087 arXiv-issued DOI via DataCite (pending registration)
Text integral sub licența deschisă a publicației · 295 cuvinte
Subiecte conexe

Introducing PIRAMID: Physics-Informed Research for Ambitious Mechanistic Interpretability
LessWrong · 25 iul. 2026

News
Quantum Computing Report · 25 iul. 2026
Beyond AHI: An Interpretable Causal-Discovery-Guided Framework for Sleep Recovery in Connected Health
arXiv · 2 sept. 2026

Natera’s intelligent appointment scheduling with Amazon Bedrock AgentCore
AWS · 26 aug. 2026