Sari la conținut

Română · beta. Traducerea a fost făcută automat și este încă în curs de revizuire. Citește pagina în engleză

perspectiva aiqbenchAI & societate

analiza aiqbench

This research introduces SightSentinel, a multi-agent AI framework designed to continuously monitor student vision by integrating calibrated probes into standard classroom displays. The system utilizes specialized agents to analyze viewing behavior and gaze stability, generating a referral score that operates strictly within safety boundaries to avoid providing medical diagnoses. By leveraging opportunistic data collection rather than scheduled screenings, this approach aims to detect undiagnosed visual impairments earlier in the educational lifecycle.
Sursă care acoperăarXiv
Ce este aceastaLectura unui model asupra articolului și a acoperirii conexe, scrisă pentru aiqbench. Nu sunt cuvintele publicației.

OptoAgent: A Trustworthy Multi-Agent Framework for Opportunistic Vision Micro-Screening in Classroom Environments

arXiv3 min de cititArticolul și perspectiva sunt în engleză.

arXiv:2609.14514v1 Announce Type: new Abstract: A child with reduced distance vision often does not know that anything is wrong. Children adapt, move closer, and rarely report the difficulty, so the problem can survive years of schooling before an adult notices. School screening addresses part of this, but it runs on a schedule, depends on staffing, and is separated from the classroom moments where the difficulty appears. Smartphone and web-based acuity tests have widened access, yet every one of them still needs somebody to start a test. We present SightSentinel, an architecture that turns a wall display a child already reads from into a recurring screening site. Ordinary educational content carries short calibrated optotype probes, and eight specialized agents divide the work. Perception agents recover viewing distance, recognition accuracy, approach behavior, gaze stability, response latency, and interocular difference from each encounter. A quality agent discards observations taken under bad geometry, poor lighting, or inattention. A longitudinal agent accumulates only the surviving evidence against the child's own baseline, and an orchestrator reports a Vision Concern Score routed through a safety gate whose output range excludes diagnosis, refraction, prescription, and reassurance. The design question is whether many cheap, noisy, well-gated encounters can reach a referral decision that one scheduled test reaches late or misses. We state the formulation, the architecture, a four-stage validation protocol against clinical reference standards, and the conditions under which the approach should be rejected.

Abstract:A child with reduced distance vision often does not know that anything is wrong. Children adapt, move closer, and rarely report the difficulty, so the problem can survive years of schooling before an adult notices. School screening addresses part of this, but it runs on a schedule, depends on staffing, and is separated from the classroom moments where the difficulty appears. Smartphone and web-based acuity tests have widened access, yet every one of them still needs somebody to start a test. We present SightSentinel, an architecture that turns a wall display a child already reads from into a recurring screening site. Ordinary educational content carries short calibrated optotype probes, and eight specialized agents divide the work. Perception agents recover viewing distance, recognition accuracy, approach behavior, gaze stability, response latency, and interocular difference from each encounter. A quality agent discards observations taken under bad geometry, poor lighting, or inattention. A longitudinal agent accumulates only the surviving evidence against the child's own baseline, and an orchestrator reports a Vision Concern Score routed through a safety gate whose output range excludes diagnosis, refraction, prescription, and reassurance. The design question is whether many cheap, noisy, well-gated encounters can reach a referral decision that one scheduled test reaches late or misses. We state the formulation, the architecture, a four-stage validation protocol against clinical reference standards, and the conditions under which the approach should be rejected.

Artificial Intelligence (cs.AI)

arXiv:2609.14514 [cs.AI]

(or arXiv:2609.14514v1 [cs.AI] for this version)

https://doi.org/10.48550/arXiv.2609.14514 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Text integral sub licența deschisă a publicației · 324 cuvinte

Subiecte conexe