analiza aiqbench

This study demonstrates that in many-body quantum batteries, extracting information about the collective coordinate yields significantly higher energy unlocking potential than measuring individual ions, scaling linearly with system size N. The research quantifies this advantage through "daemonic ergotropy," revealing strong diminishing returns where a single bit of collective information recovers a constant fraction of locked energy regardless of battery scale. These findings advance fundamental understanding of quantum thermodynamics and resource extraction in correlated systems.
Sursă care acoperăarXiv
Ce este aceastaLectura unui model asupra articolului și a acoperirii conexe, scrisă pentru aiqbench. Nu sunt cuvintele publicației.

One Bit of Collective Information Is Worth N ln 2 Bits of Local Information in a Many-Body Quantum Battery

arXiv3 min de cititArticolul și perspectiva sunt în engleză.

arXiv:2609.04730v1 Announce Type: new Abstract: Charging a quantum battery through a collective non-adiabatic stroke stores energy in a shared bosonic mode, but part remains locked in correlations with the collective spin and is inaccessible to cyclic unitaries acting on the mode alone. A demon holding one bit can unlock this energy, quantified by the daemonic ergotropy. We investigate the value of one bit and its dependence on where the information is obtained. Two protocols are compared at matched stored energy and matched information, using balanced two-outcome measurements carrying exactly one bit. We find that one bit about the collective coordinate unlocks N ln(2) times as much work as one bit about a single ion. For three stored-energy settings and N = 4-24, the measured scaling exponent is 0.990 +/- 0.043, while double extrapolation gives a prefactor of 0.69298 +/- 0.00044, within 0.02% of ln(2). To leading order, the daemonic gain equals nu mu^2 times the between-outcome variance of Jx, verified numerically to 1.3%. A balanced single-ion measurement resolves 1/4 of this variance, whereas a balanced collective split resolves (ln(2)/4)N. The microscopic origin of the prefactor remains open; a Gaussian median-split estimate of 1/(2pi) is excluded by 9%. One bit recovers a constant fraction of the locked energy independent of N and yields roughly twice as much work per bit as a complete readout, indicating strong diminishing returns. We also show that unnormalized gain comparisons can reverse the conclusion and that the break-even ion number does not collapse onto the Dicke superradiant threshold when the mode frequency is varied.

Abstract:Charging a quantum battery through a collective non-adiabatic stroke stores energy in a shared bosonic mode, but part remains locked in correlations with the collective spin and is inaccessible to cyclic unitaries acting on the mode alone. A demon holding one bit can unlock this energy, quantified by the daemonic ergotropy. We investigate the value of one bit and its dependence on where the information is obtained. Two protocols are compared at matched stored energy and matched information, using balanced two-outcome measurements carrying exactly one bit. We find that one bit about the collective coordinate unlocks N ln(2) times as much work as one bit about a single ion. For three stored-energy settings and N = 4-24, the measured scaling exponent is 0.990 +/- 0.043, while double extrapolation gives a prefactor of 0.69298 +/- 0.00044, within 0.02% of ln(2). To leading order, the daemonic gain equals nu mu^2 times the between-outcome variance of Jx, verified numerically to 1.3%. A balanced single-ion measurement resolves 1/4 of this variance, whereas a balanced collective split resolves (ln(2)/4)N. The microscopic origin of the prefactor remains open; a Gaussian median-split estimate of 1/(2pi) is excluded by 9%. One bit recovers a constant fraction of the locked energy independent of N and yields roughly twice as much work per bit as a complete readout, indicating strong diminishing returns. We also show that unnormalized gain comparisons can reverse the conclusion and that the break-even ion number does not collapse onto the Dicke superradiant threshold when the mode frequency is varied.

arXiv:2609.04730 [quant-ph]

(or arXiv:2609.04730v1 [quant-ph] for this version)

https://doi.org/10.48550/arXiv.2609.04730 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Text integral sub licența deschisă a publicației · 344 cuvinte

Subiecte conexe