analiza aiqbench
NV-Reason-CT introduces a novel architecture that preserves native 3D spatial coordinates within the language decoding process, allowing for more faithful volumetric analysis of chest and abdominal CT scans. By training on expert-annotated data and optimizing with verifiable rewards, the model demonstrates improved diagnostic metrics and significantly reduced reporting times in preliminary radiologist studies. This work advances the frontier of explainable AI in medical imaging by enabling interactive reasoning over complex 3D anatomical structures without relying on task-specific classification heads.
NV-Reason-CT: 3D Visual Language Model for CT Analysis
arXiv:2609.27511v1 Announce Type: cross Abstract: We present NV-Reason-CT, a generative vision--language model for chest and abdominal CT combining native 3D visual encoding with radiologist-guided reasoning. The model couples a native 3D vision transformer with a language model, passing all visual tokens and their explicit 3D coordinates into language decoding without further spatial token merging. This retains volumetric spatial information within the vision encoder and through the language model's positional encoding during joint processing with text. We train on a curated corpus of approximately 550,000 multimodal instruction examples from 70,111 unique CT image inputs, combining standardized reports, abnormality-focused and anatomy-specific questions, multi-turn interactions, and radiologist-authored reasoning from recorded and transcribed expert CT interpretations. Expert annotations provide direct supervision and guide additional report-grounded synthetic reasoning. End-to-end supervised fine-tuning (SFT) is followed by Group Relative Policy Optimization (GRPO), with verifiable rewards over chest and abdominal abnormality sets. The model supports abnormality classification, report generation, and interactive reasoning with reviewable observations, differential diagnoses, and uncertainty. Evaluation spans public CT benchmarks and a held-out NIH cohort. On CT-RATE, NV-Reason-CT achieves a macro-F1 of 0.614 and macro-AUROC of 0.871 without a task-specific classification head; generated reports achieve a report-derived macro-F1 of 0.592. In a preliminary study with expert radiologists, AI-assisted review received favorable confidence ratings and was associated with a 50% reduction in average reported interpretation and reporting time. We release the model and training code to support reproducible research on explainable AI for volumetric medical imaging.
Abstract:We present NV-Reason-CT, a generative vision--language model for chest and abdominal CT combining native 3D visual encoding with radiologist-guided reasoning. The model couples a native 3D vision transformer with a language model, passing all visual tokens and their explicit 3D coordinates into language decoding without further spatial token merging. This retains volumetric spatial information within the vision encoder and through the language model's positional encoding during joint processing with text. We train on a curated corpus of approximately 550,000 multimodal instruction examples from 70,111 unique CT image inputs, combining standardized reports, abnormality-focused and anatomy-specific questions, multi-turn interactions, and radiologist-authored reasoning from recorded and transcribed expert CT interpretations. Expert annotations provide direct supervision and guide additional report-grounded synthetic reasoning. End-to-end supervised fine-tuning (SFT) is followed by Group Relative Policy Optimization (GRPO), with verifiable rewards over chest and abdominal abnormality sets. The model supports abnormality classification, report generation, and interactive reasoning with reviewable observations, differential diagnoses, and uncertainty. Evaluation spans public CT benchmarks and a held-out NIH cohort. On CT-RATE, NV-Reason-CT achieves a macro-F1 of 0.614 and macro-AUROC of 0.871 without a task-specific classification head; generated reports achieve a report-derived macro-F1 of 0.592. In a preliminary study with expert radiologists, AI-assisted review received favorable confidence ratings and was associated with a 50% reduction in average reported interpretation and reporting time. We release the model and training code to support reproducible research on explainable AI for volumetric medical imaging.
Computer Vision and Pattern Recognition (cs.CV); Artificial Intelligence (cs.AI)
arXiv:2609.27511 [cs.CV]
(or arXiv:2609.27511v1 [cs.CV] for this version)
https://doi.org/10.48550/arXiv.2609.27511 Focus to learn more arXiv-issued DOI via DataCite (pending registration)
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.
Text integral sub licența deschisă a publicației · 336 cuvinte


