This research advances model-mediated tele-ultrasound by refining internal potential field models with real-time measurements to compensate for communication latency in remote diagnostics. The study demonstrates that updating voxelized patient models with measured forces significantly reduces error margins in rendered haptic feedback, enhancing image quality optimization for sonographers.
Sursă care acoperăarXiv
Ce este aceastaLectura unui model asupra articolului și a acoperirii conexe, scrisă pentru aiqbench. Nu sunt cuvintele publicației.

Measurement and Potential Field-Based Patient Modeling for Model-Mediated Tele-ultrasound

arXiv3 min de cititArticolul și perspectiva sunt în engleză.

arXiv:2509.15325v2 Announce Type: replace Abstract: Teleoperated ultrasound can improve diagnostic medical imaging access for remote communities. Having accurate force feedback is important for enabling sonographers to apply the appropriate probe contact force to optimize ultrasound image quality. However, large time delays in communication make direct force feedback impractical. Prior work investigated using point cloud-based model-mediated teleoperation and internal potential field models to estimate contact forces and torques. We expand on this by introducing a method to update the internal potential field model of the patient with measured positions, forces and torques for more transparent model-mediated tele-ultrasound. We first generate a point cloud model of the patient's surface and transmit this to the sonographer in a compact data structure. This is converted to a static voxelized volume where each voxel contains a potential field value. These values determine the forces and torques, which are rendered based on overlap between the voxelized volume and a point shell model of the ultrasound transducer. We solve for the potential field using a convex quadratic that combines the spatial Laplace operator with measured forces and torques. This was evaluated on volunteers ($n=4$) by assessing the accuracy of rendered forces and torques. Results showed the addition of measurements to the model reduced the force magnitude RMSE by an average of 7.42~N, the force vector angle error by an average of 3.71$^{\circ}$, and the torque vector angle error by an average of 64.0$^{\circ}$ compared to using only Laplace's equation.

Abstract:Teleoperated ultrasound can improve diagnostic medical imaging access for remote communities. Having accurate force feedback is important for enabling sonographers to apply the appropriate probe contact force to optimize ultrasound image quality. However, large time delays in communication make direct force feedback impractical. Prior work investigated using point cloud-based model-mediated teleoperation and internal potential field models to estimate contact forces and torques. We expand on this by introducing a method to update the internal potential field model of the patient with measured positions, forces and torques for more transparent model-mediated tele-ultrasound. We first generate a point cloud model of the patient's surface and transmit this to the sonographer in a compact data structure. This is converted to a static voxelized volume where each voxel contains a potential field value. These values determine the forces and torques, which are rendered based on overlap between the voxelized volume and a point shell model of the ultrasound transducer. We solve for the potential field using a convex quadratic that combines the spatial Laplace operator with measured forces and torques. This was evaluated on volunteers ($n=4$) by assessing the accuracy of rendered forces and torques. Results showed the addition of measurements to the model reduced the force magnitude RMSE by an average of 7.42~N, the force vector angle error by an average of 3.71$^{\circ}$, and the torque vector angle error by an average of 64.0$^{\circ}$ compared to using only Laplace's equation.

Robotics (cs.RO); Human-Computer Interaction (cs.HC)

arXiv:2509.15325 [cs.RO]

(or arXiv:2509.15325v2 [cs.RO] for this version)

https://doi.org/10.48550/arXiv.2509.15325 Focus to learn more arXiv-issued DOI via DataCite

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Text integral sub licența deschisă a publicației · 331 cuvinte

Subiecte conexe