This research introduces a Transformer-based architecture that reconstructs photoacoustic images directly from sensor data without requiring the computationally expensive system matrix during inference. By treating time-series measurements as tokens, the model achieves real-time reconstruction speeds while maintaining high fidelity against established iterative solvers like LISTA and SBTV. The approach effectively addresses the ill-posed nature of sparse-view tomography in medical imaging through advanced attention mechanisms rather than traditional compressive-sensing constraints.
Sursă care acoperăarXiv
Ce este aceastaLectura unui model asupra articolului și a acoperirii conexe, scrisă pentru aiqbench. Nu sunt cuvintele publicației.

Matrix-Free Photoacoustic Image Reconstruction via Sensor-Token Self-Attention

arXiv3 min de cititArticolul și perspectiva sunt în engleză.

arXiv:2607.25576v1 Announce Type: new Abstract: Photoacoustic tomography (PAT) combines the optical absorption contrast of biological tissue with the spatial resolution of ultrasound, yet recovering the initial pressure distribution from sparse-view sensor measurements remains an ill-posed inverse problem. Iterative compressive-sensing solvers and unrolled deep networks both retain a dependence on the system matrix at inference, which leaves real-time clinical reconstruction computationally expensive. This paper proposes the Sensor Attention Network (SAN), a Transformer-based architecture that treats the full time series of each sensor as a token and maps raw measurements directly to the reconstructed image without invoking the system matrix at inference. For training and benchmarking, an analytical k-space H-matrix is constructed and validated against the k-Wave pseudo-spectral solver under matched geometry, achieving a mean per-sensor Pearson correlation of 0.919 +/- 0.049, with k-space apodization and Gaussian temporal damping acting synergistically to reduce the energy-normalized mismatch by 49%. Trained with a vessel-weighted loss on 488 augmented samples and evaluated on 46 held-out samples against ISTA, split-Bregman total variation (SBTV), and learned ISTA (LISTA), SAN attains the highest mean SSIM (0.522) and PSNR (22.09 dB) and the lowest NMSE (0.233). Paired t-tests and Wilcoxon signed-rank tests confirm the superiority of SAN over LISTA on PSNR, NMSE, and Pearson correlation at p < 1e-8, and over ISTA and SBTV on all fidelity metrics. By bypassing the H-matrix at inference, SAN reduces reconstruction time by at least an order of magnitude, supporting real-time PAT reconstruction.

Abstract:Photoacoustic tomography (PAT) combines the optical absorption contrast of biological tissue with the spatial resolution of ultrasound, yet recovering the initial pressure distribution from sparse-view sensor measurements remains an ill-posed inverse problem. Iterative compressive-sensing solvers and unrolled deep networks both retain a dependence on the system matrix at inference, which leaves real-time clinical reconstruction computationally expensive. This paper proposes the Sensor Attention Network (SAN), a Transformer-based architecture that treats the full time series of each sensor as a token and maps raw measurements directly to the reconstructed image without invoking the system matrix at inference. For training and benchmarking, an analytical k-space H-matrix is constructed and validated against the k-Wave pseudo-spectral solver under matched geometry, achieving a mean per-sensor Pearson correlation of 0.919 +/- 0.049, with k-space apodization and Gaussian temporal damping acting synergistically to reduce the energy-normalized mismatch by 49%. Trained with a vessel-weighted loss on 488 augmented samples and evaluated on 46 held-out samples against ISTA, split-Bregman total variation (SBTV), and learned ISTA (LISTA), SAN attains the highest mean SSIM (0.522) and PSNR (22.09 dB) and the lowest NMSE (0.233). Paired t-tests and Wilcoxon signed-rank tests confirm the superiority of SAN over LISTA on PSNR, NMSE, and Pearson correlation at p < 1e-8, and over ISTA and SBTV on all fidelity metrics. By bypassing the H-matrix at inference, SAN reduces reconstruction time by at least an order of magnitude, supporting real-time PAT reconstruction.

Artificial Intelligence (cs.AI)

I.4.5; I.2.6; I.4.6; J.3

arXiv:2607.25576 [cs.AI]

(or arXiv:2607.25576v1 [cs.AI] for this version)

https://doi.org/10.48550/arXiv.2607.25576 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.