Sari la conținut

Română · beta. Traducerea a fost făcută automat și este încă în curs de revizuire. Citește pagina în engleză

perspectiva aiqbenchMachine learning

analiza aiqbench

This study rigorously evaluates the necessity of handcrafted preprocessing in dermoscopic analysis using a lightweight YOLO26 model, finding that minimal processing paired with online augmentation outperforms complex deterministic pipelines like DullRazor-CLAHE. By enforcing a strict lesion-disjoint evaluation protocol to prevent data leakage, the research demonstrates that sophisticated image enhancement often degrades both classification and segmentation accuracy without offering consistent benefits. The findings suggest that for real-time medical imaging applications, simpler input strategies combined with robust augmentation provide a superior accuracy-efficiency trade-off compared to traditional preprocessing workflows.
Sursă care acoperăarXiv
Ce este aceastaLectura unui model asupra articolului și a acoperirii conexe, scrisă pentru aiqbench. Nu sunt cuvintele publicației.

Less Is More: A Leakage-Controlled Study of Dermoscopic Preprocessing for Joint Skin Lesion Classification and Segmentation with YOLO26

arXiv3 min de cititArticolul și perspectiva sunt în engleză.

arXiv:2610.08570v1 Announce Type: new Abstract: Handcrafted preprocessing is widely employed in automated dermoscopic analysis to suppress imaging artifacts and enhance lesion visibility. Nevertheless, its actual contribution to modern real-time models remains unclear, particularly when evaluation protocols do not adequately control correlations among images of the same lesion. This study presents a leakage-controlled, lesion-disjoint evaluation of dermoscopic preprocessing and augmentation for joint multi-class lesion classification and instance segmentation using a fixed nano-scale YOLO26 segmentation model (YOLO26n-seg). From HAM10000 (10,015 images), quality control yields 10,013 valid image-mask pairs from 7,468 unique lesions, partitioned into mutually exclusive sets by lesion identity. With the architecture, resolution, training budget, and evaluation protocol held fixed, we compare minimally processed images plus online augmentation against offline class balancing, DullRazor-CLAHE preprocessing, and raw-processed hybrid views, over three random seeds. On the lesion-disjoint test set, the raw baseline achieves a mask mAP$_{50:95}$ of $0.5636 \pm 0.0234$, a Dice score of $0.9356 \pm 0.0024$, and a macro-F1 score of $0.6917 \pm 0.0202$. Offline augmentation does not improve the mean performance, while the combined and hybrid strategies reduce both class-aware segmentation and classification accuracy. At only 2.69 million parameters, the model runs at approximately 50 frames per second. Under a leakage-controlled, lesion-disjoint protocol with all non-input factors held fixed, minimally processed dermoscopic images combined with standard online augmentation deliver a better accuracy-efficiency trade-off than increasingly complex deterministic preprocessing, which yields no consistent joint benefit across three seeds on HAM10000.

Abstract:Handcrafted preprocessing is widely employed in automated dermoscopic analysis to suppress imaging artifacts and enhance lesion visibility. Nevertheless, its actual contribution to modern real-time models remains unclear, particularly when evaluation protocols do not adequately control correlations among images of the same lesion. This study presents a leakage-controlled, lesion-disjoint evaluation of dermoscopic preprocessing and augmentation for joint multi-class lesion classification and instance segmentation using a fixed nano-scale YOLO26 segmentation model (YOLO26n-seg). From HAM10000 (10,015 images), quality control yields 10,013 valid image-mask pairs from 7,468 unique lesions, partitioned into mutually exclusive sets by lesion identity. With the architecture, resolution, training budget, and evaluation protocol held fixed, we compare minimally processed images plus online augmentation against offline class balancing, DullRazor-CLAHE preprocessing, and raw-processed hybrid views, over three random seeds. On the lesion-disjoint test set, the raw baseline achieves a mask mAP$_{50:95}$ of $0.5636 \pm 0.0234$, a Dice score of $0.9356 \pm 0.0024$, and a macro-F1 score of $0.6917 \pm 0.0202$. Offline augmentation does not improve the mean performance, while the combined and hybrid strategies reduce both class-aware segmentation and classification accuracy. At only 2.69 million parameters, the model runs at approximately 50 frames per second. Under a leakage-controlled, lesion-disjoint protocol with all non-input factors held fixed, minimally processed dermoscopic images combined with standard online augmentation deliver a better accuracy-efficiency trade-off than increasingly complex deterministic preprocessing, which yields no consistent joint benefit across three seeds on HAM10000.

Machine Learning (cs.LG); Computer Vision and Pattern Recognition (cs.CV)

arXiv:2610.08570 [cs.LG]

(or arXiv:2610.08570v1 [cs.LG] for this version)

https://doi.org/10.48550/arXiv.2610.08570 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Text integral sub licența deschisă a publicației · 333 cuvinte

Subiecte conexe