This research introduces LiftXR, an interleaved deep learning framework designed to reconstruct 3D CT volumes from limited bi-planar X-ray views by decoupling spatial layout recovery from intensity estimation. By iteratively refining anatomical boundaries and calibrating region-specific intensities, the method significantly improves reconstruction fidelity compared to prior approaches without requiring full rotational data acquisition. The work advances medical imaging capabilities through novel geometric guidance strategies in inverse problems, offering potential for reduced radiation exposure scenarios where sparse-view CT is critical.
Sursă care acoperăarXiv
Ce este aceastaLectura unui model asupra articolului și a acoperirii conexe, scrisă pentru aiqbench. Nu sunt cuvintele publicației.

Learning Where and What to Lift for Bi-planar X-ray-to-CT Reconstruction

arXiv3 min de cititArticolul și perspectiva sunt în engleză.

arXiv:2608.17255v1 Announce Type: cross Abstract: X-ray imaging can be approximately modeled as the projection of an underlying volumetric attenuation field, with each measurement recording the accumulated attenuation along a corresponding ray path. Reconstructing a CT volume from only a few X-ray views is therefore severely ill-posed, as the projections collapse depth information and leave 3D locations of anatomical regions and their corresponding intensity distributions highly entangled and ambiguous. We observe that once the spatial organization of anatomical regions is established, estimating their CT intensities becomes substantially more tractable. Motivated by this, we propose LiftXR, an interleaved, geometry-guided framework that explicitly incorporates spatial layout recovery into CT reconstruction. Specifically, a layout lifter first generates a 3D anatomical layout from bi-planar X-rays, providing spatial guidance for an intensity renderer to reconstruct a CT volume. An anatomical parser then performs volumetric perception on the reconstruction, exploiting its spatially resolved boundary and intensity cues to recover a refined anatomical layout. This transition from projection-conditioned layout generation to reconstruction-conditioned anatomical perception allows the parsed layout to provide feedback for region-specific intensity calibration. Extensive experiments on two public datasets demonstrate that LiftXR consistently outperforms recent X-ray-to-CT reconstruction methods, establishing a new state of the art. Moreover, the reconstructed CT achieves superior performance in external downstream segmentation, indicating improved anatomical fidelity. Code will be released.

Abstract:X-ray imaging can be approximately modeled as the projection of an underlying volumetric attenuation field, with each measurement recording the accumulated attenuation along a corresponding ray path. Reconstructing a CT volume from only a few X-ray views is therefore severely ill-posed, as the projections collapse depth information and leave 3D locations of anatomical regions and their corresponding intensity distributions highly entangled and ambiguous. We observe that once the spatial organization of anatomical regions is established, estimating their CT intensities becomes substantially more tractable. Motivated by this, we propose LiftXR, an interleaved, geometry-guided framework that explicitly incorporates spatial layout recovery into CT reconstruction. Specifically, a layout lifter first generates a 3D anatomical layout from bi-planar X-rays, providing spatial guidance for an intensity renderer to reconstruct a CT volume. An anatomical parser then performs volumetric perception on the reconstruction, exploiting its spatially resolved boundary and intensity cues to recover a refined anatomical layout. This transition from projection-conditioned layout generation to reconstruction-conditioned anatomical perception allows the parsed layout to provide feedback for region-specific intensity calibration. Extensive experiments on two public datasets demonstrate that LiftXR consistently outperforms recent X-ray-to-CT reconstruction methods, establishing a new state of the art. Moreover, the reconstructed CT achieves superior performance in external downstream segmentation, indicating improved anatomical fidelity. Code will be released.

Computer Vision and Pattern Recognition (cs.CV); Artificial Intelligence (cs.AI)

arXiv:2608.17255 [cs.CV]

(or arXiv:2608.17255v1 [cs.CV] for this version)

https://doi.org/10.48550/arXiv.2608.17255 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Text integral sub licența deschisă a publicației · 313 cuvinte

Subiecte conexe