Knee-xRAI addresses the critical lack of reproducibility in knee osteoarthritis grading by decomposing the Kellgren-Lawrence assessment into measurable radiographic features like joint space narrowing and osteophytes. By combining a U-Net++ segmentation module with SHAP-based explainability, the framework provides an auditable decision chain that aligns with clinical workflows while achieving superior performance metrics on a large dataset. This approach offers a practical pathway to deploy transparent deep learning models in clinical settings where black-box predictions could directly impact surgical management.
Sursă care acoperăarXiv
Ce este aceastaLectura unui model asupra articolului și a acoperirii conexe, scrisă pentru aiqbench. Nu sunt cuvintele publicației.

Knee-xRAI: An Explainable AI Framework for Automatic Kellgren-Lawrence Grading of Knee Osteoarthritis

arXiv3 min de cititArticolul și perspectiva sunt în engleză.

arXiv:2604.23435v2 Announce Type: replace-cross Abstract: Grading knee osteoarthritis (KOA) on plain radiographs is poorly reproducible across readers. A single-grade disagreement on the Kellgren-Lawrence (KL) scale can alter surgical management or redirect a patient from conservative therapy to intra-articular injection. Meanwhile, deep learning models that outperform human readers often offer no explanation for their decisions. We present Knee-xRAI, a pipeline that decomposes the grading process by mimicking clinical radiological workflows. It independently measures joint space narrowing (JSN), osteophytes, and subchondral sclerosis, then combines these findings into an explainable KL grade. Specifically, a U-Net++ architecture quantifies JSN via contour segmentation, an SE-ResNet-50 multi-task network grades osteophytes per anatomical site on the OARSI scale, and a hybrid texture-CNN detects binary sclerosis. This pipeline yields a 50-dimensional feature vector evaluated via an XGBoost-SHAP classifier (Path A, audit) and a ConvNeXt hybrid predictor (Path B, deployed). On 8,260 OAI-derived radiographs, the JSN module achieved a Dice score of 0.8909 and an mJSW ICC of 0.8674. Path A reached a QWK of 0.6294 and an AUC of 0.8046, confirming the structured feature vector carries substantial diagnostic signal. Path B achieved a QWK of 0.8436 and an AUC of 0.9017. SHAP analysis identifies JSN as the dominant feature, with osteophytes adding a consistent increment and sclerosis contributing marginally. Removing JSN evidence collapses KL3-KL4 recall while early grades remain intact, aligning with the KL diagnostic criteria. Knee-xRAI grounds every prediction in an auditable chain of measured radiographic findings, providing clinical transparency at the point of care.

Abstract:Grading knee osteoarthritis (KOA) on plain radiographs is poorly reproducible across readers. A single-grade disagreement on the Kellgren-Lawrence (KL) scale can alter surgical management or redirect a patient from conservative therapy to intra-articular injection. Meanwhile, deep learning models that outperform human readers often offer no explanation for their decisions. We present Knee-xRAI, a pipeline that decomposes the grading process by mimicking clinical radiological workflows. It independently measures joint space narrowing (JSN), osteophytes, and subchondral sclerosis, then combines these findings into an explainable KL grade. Specifically, a U-Net++ architecture quantifies JSN via contour segmentation, an SE-ResNet-50 multi-task network grades osteophytes per anatomical site on the OARSI scale, and a hybrid texture-CNN detects binary sclerosis. This pipeline yields a 50-dimensional feature vector evaluated via an XGBoost-SHAP classifier (Path A, audit) and a ConvNeXt hybrid predictor (Path B, deployed). On 8,260 OAI-derived radiographs, the JSN module achieved a Dice score of 0.8909 and an mJSW ICC of 0.8674. Path A reached a QWK of 0.6294 and an AUC of 0.8046, confirming the structured feature vector carries substantial diagnostic signal. Path B achieved a QWK of 0.8436 and an AUC of 0.9017. SHAP analysis identifies JSN as the dominant feature, with osteophytes adding a consistent increment and sclerosis contributing marginally. Removing JSN evidence collapses KL3-KL4 recall while early grades remain intact, aligning with the KL diagnostic criteria. Knee-xRAI grounds every prediction in an auditable chain of measured radiographic findings, providing clinical transparency at the point of care.

Computer Vision and Pattern Recognition (cs.CV); Artificial Intelligence (cs.AI); Machine Learning (cs.LG)

arXiv:2604.23435 [cs.CV]

(or arXiv:2604.23435v2 [cs.CV] for this version)

https://doi.org/10.48550/arXiv.2604.23435 Focus to learn more arXiv-issued DOI via DataCite

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Text integral sub licența deschisă a publicației · 344 cuvinte

Subiecte conexe