analiza aiqbench
KAISEN introduces a rigorous five-phase audit pipeline for clinical risk models that stress-tests fairness components against failure modes rather than relying on unverified assumptions. The research highlights critical limitations in current calibration methods like Platt scaling under proxy misspecification and demonstrates that drift monitoring signals are heavily dependent on specific cohort seeds, challenging the portability of standard thresholds across different patient populations.
KAISEN: Reproducible Subgroup Fairness Auditing for Clinical Risk Models
arXiv:2607.28608v1 Announce Type: new Abstract: Clinical risk models routinely achieve strong aggregate performance while producing materially different error rates across patient subgroups. Audit pipelines have been proposed to catch this, but their components are rarely stress-tested, so it is unclear which parts of an audit can be trusted and under what conditions. We present KAISEN, a five-phase audit pipeline covering subgroup stratification, disparity measurement, mechanism diagnostics, post-hoc mitigation, and drift monitoring, evaluated to the point of failure on a synthetic benchmark of 16 disease tasks, 15 social-determinant axes from Healthy People 2030, and three prespecified intersections. Four findings follow. (i) Significance tracks each axis's gap against its own minimum detectable effect: rank correlation between significance count and raw equalized-odds difference (EOD) across the 15 axes is rho = 0.56, rising to rho = 0.78 once EOD is standardized by that floor. (ii) Per-group threshold optimization reduces EOD in 48 of 48 held-out runs (paired delta = -0.285, 95% CI [-0.313, -0.252]), while group-wise Platt scaling -- the better calibrator -- behaves as a coin flip on EOD (19 of 48 runs improved, 95% CI [0.26, 0.55]) with mean effect near zero, so what an audit should report is the variance, not the average. (iii) The mechanism diagnostic classifies 144 of 144 controlled cases correctly but recovers none of 48 model-driven cases under proxy misspecification, with no signal that it failed. (iv) CUSUM failures and false alarms track cohort realization far more than disease: at the reference threshold, all 27 false alarms and 7 of 8 missed shifts come from different seeds (chi-squared p = 0.002), so a threshold tuned on one cohort fails to transfer. All results are synthetic with known ground truth and do not establish clinical validity. Code, artifacts, and scripts reproducing every number are released.
Abstract:Clinical risk models routinely achieve strong aggregate performance while producing materially different error rates across patient subgroups. Audit pipelines have been proposed to catch this, but their components are rarely stress-tested, so it is unclear which parts of an audit can be trusted and under what conditions. We present KAISEN, a five-phase audit pipeline covering subgroup stratification, disparity measurement, mechanism diagnostics, post-hoc mitigation, and drift monitoring, evaluated to the point of failure on a synthetic benchmark of 16 disease tasks, 15 social-determinant axes from Healthy People 2030, and three prespecified intersections. Four findings follow. (i) Significance tracks each axis's gap against its own minimum detectable effect: rank correlation between significance count and raw equalized-odds difference (EOD) across the 15 axes is rho = 0.56, rising to rho = 0.78 once EOD is standardized by that floor. (ii) Per-group threshold optimization reduces EOD in 48 of 48 held-out runs (paired delta = -0.285, 95% CI [-0.313, -0.252]), while group-wise Platt scaling -- the better calibrator -- behaves as a coin flip on EOD (19 of 48 runs improved, 95% CI [0.26, 0.55]) with mean effect near zero, so what an audit should report is the variance, not the average. (iii) The mechanism diagnostic classifies 144 of 144 controlled cases correctly but recovers none of 48 model-driven cases under proxy misspecification, with no signal that it failed. (iv) CUSUM failures and false alarms track cohort realization far more than disease: at the reference threshold, all 27 false alarms and 7 of 8 missed shifts come from different seeds (chi-squared p = 0.002), so a threshold tuned on one cohort fails to transfer. All results are synthetic with known ground truth and do not establish clinical validity. Code, artifacts, and scripts reproducing every number are released.
Machine Learning (cs.LG); Quantitative Methods (q-bio.QM)
arXiv:2607.28608 [cs.LG]
(or arXiv:2607.28608v1 [cs.LG] for this version)
https://doi.org/10.48550/arXiv.2607.28608 Focus to learn more arXiv-issued DOI via DataCite (pending registration)
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.
Text integral sub licența deschisă a publicației · 390 cuvinte
Subiecte conexe

AI in healthcare: applications and best practices
Databricks · 24 iul. 2026

[AINews] not much happened today
Latent Space · 10 sept. 2026
Evaluating Intersectional Fairness across Clinical Machine Learning Use Cases using Fairlogue and the All of Us Research Program
arXiv · 17 iun. 2026

Concrete Evaluations to Investigate the OpenAI Model That Hacked Hugging Face
AI Alignment Forum · 3 aug. 2026