În afara temei aiqbench
Această știre a fost preluată de la o sursă pe care o urmărim, dar nu ține de domeniul AI sau cuantic, așa că nu există o perspectivă aiqbench pentru ea.
Information-based Unified Design Framework for NMR Magnetic Tracking System
arXiv:2610.17873v1 Announce Type: new Abstract: Nuclear magnetic resonance (NMR) magnetic tracking offers a promising alternative to magnetic resonance imaging (MRI)-based localization for medical robotic guidance. However, scalar field measurements and field-aligned marker moments constrain position and orientation tracking, requiring careful configuration design. We present a unified information-based framework that uses local covariance analysis to evaluate receiver geometry, marker separation, and external source configuration in on/off-board NMR tracking. Numerical evaluation shows that planar-array precision depends jointly on receiver count and geometry, with triangular lattice arrays achieving the lowest best-case position uncertainty among the evaluated layouts for 9--20 receivers. Two spatially separated, field-aligned markers enable device-axis tracking, with predicted angular uncertainty below $2^\circ$ at the evaluated workspace center for suitable marker separations. We further establish point-dipole source--receiver duality, unifying the analysis of on/off-board NMR tracking. These
Abstract:Nuclear magnetic resonance (NMR) magnetic tracking offers a promising alternative to magnetic resonance imaging (MRI)-based localization for medical robotic guidance. However, scalar field measurements and field-aligned marker moments constrain position and orientation tracking, requiring careful configuration design. We present a unified information-based framework that uses local covariance analysis to evaluate receiver geometry, marker separation, and external source configuration in on/off-board NMR tracking. Numerical evaluation shows that planar-array precision depends jointly on receiver count and geometry, with triangular lattice arrays achieving the lowest best-case position uncertainty among the evaluated layouts for 9--20 receivers. Two spatially separated, field-aligned markers enable device-axis tracking, with predicted angular uncertainty below $2^\circ$ at the evaluated workspace center for suitable marker separations. We further establish point-dipole source--receiver duality, unifying the analysis of on/off-board NMR tracking. These
Robotics (cs.RO); Systems and Control (eess.SY)
arXiv:2610.17873 [cs.RO]
(or arXiv:2610.17873v1 [cs.RO] for this version)
https://doi.org/10.48550/arXiv.2610.17873 Focus to learn more arXiv-issued DOI via DataCite (pending registration)
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.
Text integral sub licența deschisă a publicației · 226 cuvinte

