Sari la conținut

Română · beta. Traducerea a fost făcută automat și este încă în curs de revizuire. Citește pagina în engleză

perspectiva aiqbenchCercetare AI

analiza aiqbench

This research presents a significant advancement in medical robotics by deploying Transformer and TCN networks to fuse multimodal sensory data for real-time trajectory adjustment during high-risk craniotomy procedures. The closed-loop system effectively compensates for tissue deformation and registration errors, achieving near-perfect breakthrough detection accuracy without dural injury in ex vivo trials. Such cybernetic frameworks represent a critical step toward fully autonomous surgical robots capable of handling complex intraoperative dynamics safely.
Sursă care acoperăarXiv
Ce este aceastaLectura unui model asupra articolului și a acoperirii conexe, scrisă pentru aiqbench. Nu sunt cuvintele publicației.

Human-Inspired Framework for Robotic Craniotomy: Integrating Multimodal Fusion and Adaptive Trajectory Adjustment

arXiv3 min de cititArticolul și perspectiva sunt în engleză.

arXiv:2607.21058v1 Announce Type: new Abstract: Manual craniotomy is a high-risk, skill-dependent procedure associated with surgeon fatigue and potential dural injury. While robotic approaches have improved safety, existing open-loop systems rely solely on preoperative images and cannot compensate for intraoperative registration errors or tissue deformation. To address this, we propose a human-inspired closed-loop robotic craniotomy framework that intelligently integrates preoperative planning with intraoperative execution. An adaptive dual-contour fusion algorithm is employed to generate trajectories that conform to complex cranial geometries while maintaining a consistent tool-bone relative pose. For intraoperative perception, a multimodal two-stage cross-modal attention block (CMA)-temporal convolutional network (TCN)-Transformer network combined with an adaptive Bayesian filter fuses force and acoustic signals to achieve robust breakthrough detection under varying bone conditions. Upon detection, an in-situ projection-based trajectory adjustment strategy dynamically compensates for depth deviations, enabling safe residual bone isolation. Experiments on bovine ribs show a breakthrough prediction accuracy of 97%, a detection latency of 0.048 +/- 0.097 s, and a maximum overshoot of 0.29 mm. All four ex vivo cranial experiments were successfully completed without dural injury. These results demonstrate that the proposed cybernetic framework enables safe and autonomous craniotomy with highly effective closed-loop control.

Abstract:Manual craniotomy is a high-risk, skill-dependent procedure associated with surgeon fatigue and potential dural injury. While robotic approaches have improved safety, existing open-loop systems rely solely on preoperative images and cannot compensate for intraoperative registration errors or tissue deformation. To address this, we propose a human-inspired closed-loop robotic craniotomy framework that intelligently integrates preoperative planning with intraoperative execution. An adaptive dual-contour fusion algorithm is employed to generate trajectories that conform to complex cranial geometries while maintaining a consistent tool-bone relative pose. For intraoperative perception, a multimodal two-stage cross-modal attention block (CMA)-temporal convolutional network (TCN)-Transformer network combined with an adaptive Bayesian filter fuses force and acoustic signals to achieve robust breakthrough detection under varying bone conditions. Upon detection, an in-situ projection-based trajectory adjustment strategy dynamically compensates for depth deviations, enabling safe residual bone isolation. Experiments on bovine ribs show a breakthrough prediction accuracy of 97%, a detection latency of 0.048 +/- 0.097 s, and a maximum overshoot of 0.29 mm. All four ex vivo cranial experiments were successfully completed without dural injury. These results demonstrate that the proposed cybernetic framework enables safe and autonomous craniotomy with highly effective closed-loop control.

Robotics (cs.RO)

arXiv:2607.21058 [cs.RO]

(or arXiv:2607.21058v1 [cs.RO] for this version)

https://doi.org/10.48550/arXiv.2607.21058 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.