Sari la conținut

Română · beta. Traducerea a fost făcută automat și este încă în curs de revizuire. Citește pagina în engleză

perspectiva aiqbenchProduse AI

analiza aiqbench

This study introduces the PhotoMOCI dataset and benchmarks generative AI techniques, specifically GANs and diffusion models, for enhancing oral lesion classification. The authors propose a Synthetic Image Filter (SIF) that effectively selects high-quality synthetic samples, yielding measurable accuracy gains over traditional augmentation methods while filtering out misleading data. This work advances the practical application of generative models in medical computer vision by addressing the critical challenge of limited annotated datasets.
Sursă care acoperăarXiv
Ce este aceastaLectura unui model asupra articolului și a acoperirii conexe, scrisă pentru aiqbench. Nu sunt cuvintele publicației.

Generative AI-Based Data Augmentation for Oral Lesion Classification: The PhotoMOCI Dataset and Benchmark

arXiv3 min de cititArticolul și perspectiva sunt în engleză.

arXiv:2609.35226v1 Announce Type: cross Abstract: Early detection of oral cancer via photographic imaging presents a promising avenue for large-scale oral cavity screening. However, the development of robust deep learning models is frequently hampered by the scarcity of high-quality, annotated datasets. To address this limitation, a novel and well-curated resource, the Photographic Multi-purpose Oral Cancer Imaging (PhotoMOCI) dataset, is introduced for developing models across multiple diagnostic tasks in oral oncology. Then, a comprehensive benchmark study was conducted to investigate how various data augmentation strategies influence the performance of image classifiers. Our analysis spans different generative AI frameworks, evaluating the efficacy of traditional methods against advanced generative approaches, including Generative Adversarial Networks (GANs) and Diffusion Models (DMs). Additionally, we propose the Synthetic Image Filter (SIF), a mechanism to select specific samples based on two auxiliary models: Synthetic Proxy Classifier to ensure samples are representative of the target class and Synthetic Image Detector to verify they appear realistic, thereby selecting only the high-utility images that contribute to improving downstream performance. Across the evaluated datasets and classifiers, the best SIF-filtered setup improves accuracy over traditional augmentation in all cases, with gains of +1.73% and +2.35% on PhotoMOCI and +2.38% and +2.08% on KOCD for ResNet50 and ViT, respectively. Our findings reveal that while the direct application of generative data augmentation may yield performance drops, the integration of SIF, considering (i) how synthetic data looks real and (ii) how it reflects the discriminative features of the belonging class, provides a simple yet effective mechanism to filter out synthetic samples that confuse the classifier during training.

Abstract:Early detection of oral cancer via photographic imaging presents a promising avenue for large-scale oral cavity screening. However, the development of robust deep learning models is frequently hampered by the scarcity of high-quality, annotated datasets. To address this limitation, a novel and well-curated resource, the Photographic Multi-purpose Oral Cancer Imaging (PhotoMOCI) dataset, is introduced for developing models across multiple diagnostic tasks in oral oncology. Then, a comprehensive benchmark study was conducted to investigate how various data augmentation strategies influence the performance of image classifiers. Our analysis spans different generative AI frameworks, evaluating the efficacy of traditional methods against advanced generative approaches, including Generative Adversarial Networks (GANs) and Diffusion Models (DMs). Additionally, we propose the Synthetic Image Filter (SIF), a mechanism to select specific samples based on two auxiliary models: Synthetic Proxy Classifier to ensure samples are representative of the target class and Synthetic Image Detector to verify they appear realistic, thereby selecting only the high-utility images that contribute to improving downstream performance. Across the evaluated datasets and classifiers, the best SIF-filtered setup improves accuracy over traditional augmentation in all cases, with gains of +1.73% and +2.35% on PhotoMOCI and +2.38% and +2.08% on KOCD for ResNet50 and ViT, respectively. Our findings reveal that while the direct application of generative data augmentation may yield performance drops, the integration of SIF, considering (i) how synthetic data looks real and (ii) how it reflects the discriminative features of the belonging class, provides a simple yet effective mechanism to filter out synthetic samples that confuse the classifier during training.

Computer Vision and Pattern Recognition (cs.CV); Artificial Intelligence (cs.AI)

arXiv:2609.35226 [cs.CV]

(or arXiv:2609.35226v1 [cs.CV] for this version)

https://doi.org/10.48550/arXiv.2609.35226 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Text integral sub licența deschisă a publicației · 355 cuvinte

Subiecte conexe