Sari la conținut

Română · beta. Traducerea a fost făcută automat și este încă în curs de revizuire. Citește pagina în engleză

perspectiva aiqbenchMachine learning

analiza aiqbench

This comparative study clarifies how deep learning architecture performance in physiological emotion recognition varies by dataset characteristics rather than adhering to a single superior model. The research demonstrates that multimodal sensing consistently outperforms single-sensor configurations, while identifying 4 Hz as an optimal sampling frequency that balances accuracy with reduced training costs. These findings offer practical guidance for deploying affective computing systems on wearable devices without relying on uniformly dominant architectures.
Sursă care acoperăarXiv
Ce este aceastaLectura unui model asupra articolului și a acoperirii conexe, scrisă pentru aiqbench. Nu sunt cuvintele publicației.

From Stress to Affect: Multimodal Deep Learning for Physiological Emotion Recognition Across Wearable Sensor Modalities

arXiv3 min de cititArticolul și perspectiva sunt în engleză.

arXiv:2609.20991v1 Announce Type: new Abstract: Physiological emotion recognition using wearable sensors has important applications in mental health monitoring, affective computing, and human-computer interaction. However, existing studies typically evaluate a single model, sensing configuration, or dataset, limiting our understanding of how these factors influence recognition performance. We present a comparative study of temporal deep learning architectures for physiological emotion recognition using two multimodal wearable datasets: WESAD and EmoWear. Bidirectional long short-term memory (LSTM), temporal convolutional network (TCN), and Transformer models are evaluated under wrist-only, chest-only, and multimodal sensing configurations using participant-independent leave-one-subject-out cross-validation (LOSO-CV). We also investigate soft-voting ensembles, sensor ablation, sampling frequency, and gradient-based saliency. The Transformer achieved the highest multimodal accuracy on WESAD (99.02% +/- 0.51%), whereas the LSTM achieved the best multimodal accuracy on EmoWear for both arousal (91.80% +/- 1.06%) and valence (89.96% +/- 0.36%). These results show that relative architecture performance depends on dataset characteristics rather than one architecture being uniformly superior. Multimodal sensing consistently outperformed wrist-only and chest-only configurations across both datasets. Sampling-frequency analysis showed that 4 Hz provides a practical operating point, with performance comparable to higher frequencies at substantially lower training cost. These findings provide guidance for selecting architectures, sensing modalities, and sampling frequencies for wearable physiological emotion recognition.

Abstract:Physiological emotion recognition using wearable sensors has important applications in mental health monitoring, affective computing, and human-computer interaction. However, existing studies typically evaluate a single model, sensing configuration, or dataset, limiting our understanding of how these factors influence recognition performance. We present a comparative study of temporal deep learning architectures for physiological emotion recognition using two multimodal wearable datasets: WESAD and EmoWear. Bidirectional long short-term memory (LSTM), temporal convolutional network (TCN), and Transformer models are evaluated under wrist-only, chest-only, and multimodal sensing configurations using participant-independent leave-one-subject-out cross-validation (LOSO-CV). We also investigate soft-voting ensembles, sensor ablation, sampling frequency, and gradient-based saliency. The Transformer achieved the highest multimodal accuracy on WESAD (99.02% +/- 0.51%), whereas the LSTM achieved the best multimodal accuracy on EmoWear for both arousal (91.80% +/- 1.06%) and valence (89.96% +/- 0.36%). These results show that relative architecture performance depends on dataset characteristics rather than one architecture being uniformly superior. Multimodal sensing consistently outperformed wrist-only and chest-only configurations across both datasets. Sampling-frequency analysis showed that 4 Hz provides a practical operating point, with performance comparable to higher frequencies at substantially lower training cost. These findings provide guidance for selecting architectures, sensing modalities, and sampling frequencies for wearable physiological emotion recognition.

Machine Learning (cs.LG)

arXiv:2609.20991 [cs.LG]

(or arXiv:2609.20991v1 [cs.LG] for this version)

https://doi.org/10.48550/arXiv.2609.20991 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Text integral sub licența deschisă a publicației · 295 cuvinte

Subiecte conexe