Sari la conținut

Română · beta. Traducerea a fost făcută automat și este încă în curs de revizuire. Citește pagina în engleză

perspectiva aiqbenchMachine learning

analiza aiqbench

This research introduces a lightweight "prototype-only" adaptation method for TinyML ECG systems, enabling microcontrollers like the PSoC 6 to personalize arrhythmia detection on-device without expensive backpropagation. By freezing a pre-trained feature extractor and updating only a small embedding space, the approach significantly improves accuracy across different patients while minimizing memory usage and computational latency. This technique addresses a critical bottleneck in wearable health tech by making robust, individualized AI inference feasible on resource-constrained medical hardware.
Sursă care acoperăarXiv
Ce este aceastaLectura unui model asupra articolului și a acoperirii conexe, scrisă pentru aiqbench. Nu sunt cuvintele publicației.

Few-Shot Prototype Head Adaptation for On-Device ECG Personalization on PSoC~6

arXiv3 min de cititArticolul și perspectiva sunt în engleză.

arXiv:2610.06241v1 Announce Type: cross Abstract: Wearable and bedside electrocardiogram (ECG) monitors must adapt to patient-specific morphology to maintain arrhythmia detection accuracy across users, yet personalization is typically performed offline and cannot account for individual physiology, electrode placement, or recording drift. On-device adaptation by backpropagation is expensive for microcontroller-class medical devices because it requires an optimizer state, repeated backward passes through convolutional layers, and labeled arrhythmic beats that may not be available at deployment time. This letter proposes prototype-only head adaptation as a compact personalization primitive for TinyML ECG systems. A one-dimensional convolutional neural network (1-D CNN; 1,314 parameters and 72.6k multiply-accumulate operations per beat) is trained offline on the MIT-BIH Arrhythmia Database under an inter-patient protocol, frozen as a feature extractor, and exported to a PSoC 6 microcontroller. Patient-specific adaptation then reduces to computing closed-form class means in a 32-dimensional embedding space, requiring no convolutional backward pass, no iterative optimization, and only one forward pass per support beat. Prototype adaptation improves inter-patient macro-F1 from 0.635/0.639/0.646 to 0.731/0.771/0.797 at 1/5/10-shot, outperforming linear stochastic-gradient-descent (SGD) head fine-tuning at every shot count for the target tiny backbone. On-device replay over 18 one-shot episodes on a PSoC 6 Cortex-M4F matches the host macro-F1 for the prototype head (0.798), with 11.39 ms per beat, 5.2 KB flash, and 22.2 KB SRAM. A restricted variant that updates only the normal-class prototype from passively buffered sinus beats yields a consistent +0.05 macro-F1 gain, reducing the annotation burden during initial

Abstract:Wearable and bedside electrocardiogram (ECG) monitors must adapt to patient-specific morphology to maintain arrhythmia detection accuracy across users, yet personalization is typically performed offline and cannot account for individual physiology, electrode placement, or recording drift. On-device adaptation by backpropagation is expensive for microcontroller-class medical devices because it requires an optimizer state, repeated backward passes through convolutional layers, and labeled arrhythmic beats that may not be available at deployment time. This letter proposes prototype-only head adaptation as a compact personalization primitive for TinyML ECG systems. A one-dimensional convolutional neural network (1-D CNN; 1,314 parameters and 72.6k multiply-accumulate operations per beat) is trained offline on the MIT-BIH Arrhythmia Database under an inter-patient protocol, frozen as a feature extractor, and exported to a PSoC 6 microcontroller. Patient-specific adaptation then reduces to computing closed-form class means in a 32-dimensional embedding space, requiring no convolutional backward pass, no iterative optimization, and only one forward pass per support beat. Prototype adaptation improves inter-patient macro-F1 from 0.635/0.639/0.646 to 0.731/0.771/0.797 at 1/5/10-shot, outperforming linear stochastic-gradient-descent (SGD) head fine-tuning at every shot count for the target tiny backbone. On-device replay over 18 one-shot episodes on a PSoC 6 Cortex-M4F matches the host macro-F1 for the prototype head (0.798), with 11.39 ms per beat, 5.2 KB flash, and 22.2 KB SRAM. A restricted variant that updates only the normal-class prototype from passively buffered sinus beats yields a consistent +0.05 macro-F1 gain, reducing the annotation burden during initial

Machine Learning (cs.LG); Artificial Intelligence (cs.AI)

arXiv:2610.06241 [cs.LG]

(or arXiv:2610.06241v1 [cs.LG] for this version)

https://doi.org/10.48550/arXiv.2610.06241 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Text integral sub licența deschisă a publicației · 334 cuvinte

Subiecte conexe