Sari la conținut

Română · beta. Traducerea a fost făcută automat și este încă în curs de revizuire. Citește pagina în engleză

perspectiva aiqbenchProduse AI

analiza aiqbench

This research demonstrates a parameter-efficient fine-tuning approach that adapts a general multimodal wearable backbone specifically for women's health metrics without retraining the entire encoder. By freezing most of the pretrained weights and training only low-rank adapters, the model achieves significant improvements in cycle-phase detection and symptom prediction while maintaining performance on broader benchmarks. The study highlights the viability of specialized foundation models for niche medical applications using minimal computational resources.
Sursă care acoperăarXiv
Ce este aceastaLectura unui model asupra articolului și a acoperirii conexe, scrisă pentru aiqbench. Nu sunt cuvintele publicației.

FemWear: A Parameter-Efficient Wearable Foundation Model for Women's Health

arXiv3 min de cititArticolul și perspectiva sunt în engleză.

arXiv:2608.08244v2 Announce Type: replace Abstract: General-purpose wearable foundation models are pretrained on broad sensor streams and populations, but their representations are not organized around women's health. FemWear is a women's wearable foundation model, obtained by parameter-efficiently repurposing a pretrained general multimodal wearable backbone into a specialized representation for women's health. It keeps the pretrained patch projection and Transformer encoder frozen and trains 239,236 encoder parameters - 1.11% of a 21.54M-parameter encoder - through low-rank residual adapters and causal task-family heads, producing one shared longitudinal representation for menstrual, symptom, affective, sleep/recovery, autonomic, activity, and pregnancy outcomes. We evaluate six cohorts with 63 comparable primary metrics, 33 from women's-health cohorts, while retaining the 32-task OpenMHC ability-retention benchmark. On a fixed participant split over three seeds, FemWear improved cycle-phase macro-F1 by 8.15% and reduced mean absolute error for cramps, mood symptoms, and sleep problems by 9.32%, 5.80%, and 9.43%; 24-hour onset AUPRC decreased by 3.40%. A stricter 42-participant nested leave-one-participant-out audit retained positive changes for 24-hour onset (+2.87%), 72-hour onset (+6.35%), and cramps (+2.19%), while phase, mood, and sleep changes were neutral or negative and no endpoint had a strictly positive corrected confidence interval. Capacity-matched experiments beat a latest-day multilayer perceptron but not shared-GRU or multi-gate mixture-of-experts baselines. Train-only calibration reduced onset expected calibration error by 84.2-88.2% with zero temporal-nesting violations. FemWear is therefore a women's wearable foundation model: a reproducible, parameter-efficient specialization delivering targeted transfer across women's-health tasks and coherent probability outputs.

Abstract:General-purpose wearable foundation models are pretrained on broad sensor streams and populations, but their representations are not organized around women's health. FemWear is a women's wearable foundation model, obtained by parameter-efficiently repurposing a pretrained general multimodal wearable backbone into a specialized representation for women's health. It keeps the pretrained patch projection and Transformer encoder frozen and trains 239,236 encoder parameters - 1.11% of a 21.54M-parameter encoder - through low-rank residual adapters and causal task-family heads, producing one shared longitudinal representation for menstrual, symptom, affective, sleep/recovery, autonomic, activity, and pregnancy outcomes. We evaluate six cohorts with 63 comparable primary metrics, 33 from women's-health cohorts, while retaining the 32-task OpenMHC ability-retention benchmark. On a fixed participant split over three seeds, FemWear improved cycle-phase macro-F1 by 8.15% and reduced mean absolute error for cramps, mood symptoms, and sleep problems by 9.32%, 5.80%, and 9.43%; 24-hour onset AUPRC decreased by 3.40%. A stricter 42-participant nested leave-one-participant-out audit retained positive changes for 24-hour onset (+2.87%), 72-hour onset (+6.35%), and cramps (+2.19%), while phase, mood, and sleep changes were neutral or negative and no endpoint had a strictly positive corrected confidence interval. Capacity-matched experiments beat a latest-day multilayer perceptron but not shared-GRU or multi-gate mixture-of-experts baselines. Train-only calibration reduced onset expected calibration error by 84.2-88.2% with zero temporal-nesting violations. FemWear is therefore a women's wearable foundation model: a reproducible, parameter-efficient specialization delivering targeted transfer across women's-health tasks and coherent probability outputs.

Artificial Intelligence (cs.AI)

arXiv:2608.08244 [cs.AI]

(or arXiv:2608.08244v2 [cs.AI] for this version)

https://doi.org/10.48550/arXiv.2608.08244 Focus to learn more arXiv-issued DOI via DataCite

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Text integral sub licența deschisă a publicației · 327 cuvinte

Subiecte conexe