This study demonstrates that logically equivalent quantum circuit compilations yield measurably different fidelities on a three-qubit NMR processor due to variations in pulse timing and control ordering rather than unitary differences. The findings highlight the sensitivity of state preparation accuracy to specific implementation details, challenging the assumption that compilation choices are irrelevant for small-scale quantum devices.
Experimental characterisation of compilation-dependent Grover--Rudolph probability distribution loading on a three-qubit NMR processor
De la arXiv
Text integralarXiv:2611.34433v1 Announce Type: new Abstract: Exact state-preparation circuits are normally judged by how closely the measured output distribution reproduces the target. Using the ancilla-free Grover-Rudolph construction compiled into {Ry, X, CNOT}, we ask instead how much the accuracy of a probability-distribution loading depends on which of several logically equivalent compilations is executed. Two Gray-code realisations of the level-2 uniformly controlled rotation, A and B, differ only in the order of their CNOT controls: same unitary, same angles.
On a three-qubit liquid-state NMR processor they do not perform identically. Across 700 runs over seven targets the A/B contrast is significant for 3 of them under Holm, with no fixed sign. Two further campaigns isolate the effect within one unit. Removing the circuit's identity-equivalent gates, which changes the executed schedule but not the unitary, affects the two realisations differently: a ladder x intervention interaction of +0.0625 (95% CI [+0.0306, +0.0944], paired p = 4.8e-4), reversing the sign of the A/B advantage.
Across five acquisitions of this one logical circuit the contrast runs from +0.0395 to -0.0229. Not every compilation choice matters: commanding the two level-1 inverse rotations as 720 deg - theta rather than -theta, with the gate list unchanged, moves the mean fidelity by -0.0006 ([-0.0157, +0.0146]) on one target in one session. We offer the order and timing of the executed pulses as the hypothesis these observations favour, without identifying a mechanism.
The metric does not certify coherences, and the measured correlators are inconsistent with any global depolarising description: on the uniform target, at a classical fidelity of 0.962, a two-body correlation of +0.217 appears where the target has none. Run-level data and code are deposited for every campaign run on our own unit; the pulse-level campaign is reported from summary tables.
Abstract:Exact state-preparation circuits are normally judged by how closely the measured output distribution reproduces the target. Using the ancilla-free Grover-Rudolph construction compiled into {Ry, X, CNOT}, we ask instead how much the accuracy of a probability-distribution loading depends on which of several logically equivalent compilations is executed. Two Gray-code realisations of the level-2 uniformly controlled rotation, A and B, differ only in the order of their CNOT controls: same unitary, same angles.
On a three-qubit liquid-state NMR processor they do not perform identically. Across 700 runs over seven targets the A/B contrast is significant for 3 of them under Holm, with no fixed sign. Two further campaigns isolate the effect within one unit. Removing the circuit's identity-equivalent gates, which changes the executed schedule but not the unitary, affects the two realisations differently: a ladder x intervention interaction of +0.0625 (95% CI [+0.0306, +0.0944], paired p = 4.8e-4), reversing the sign of the A/B advantage.
Across five acquisitions of this one logical circuit the contrast runs from +0.0395 to -0.0229. Not every compilation choice matters: commanding the two level-1 inverse rotations as 720 deg - theta rather than -theta, with the gate list unchanged, moves the mean fidelity by -0.0006 ([-0.0157, +0.0146]) on one target in one session. We offer the order and timing of the executed pulses as the hypothesis these observations favour, without identifying a mechanism.
The metric does not certify coherences, and the measured correlators are inconsistent with any global depolarising description: on the uniform target, at a classical fidelity of 0.962, a two-body correlation of +0.217 appears where the target has none. Run-level data and code are deposited for every campaign run on our own unit; the pulse-level campaign is reported from summary tables.
| Subjects: | Quantum Physics (quant-ph) |
| Cite as: | arXiv:2611.34433 [quant-ph] |
| (or arXiv:2611.34433v1 [quant-ph] for this version) | |
| https://doi.org/10.48550/arXiv.2611.34433 arXiv-issued DOI via DataCite (pending registration) |
Text integral sub licența deschisă a publicației · 308 cuvinte
Alte relatări ale acestei știri
- arXiv · acest articol
- Quantum Zeitgeist · Three-qubit NMR processor shows compilation affects accuracy