Sari la conținut

Română · beta. Traducerea a fost făcută automat și este încă în curs de revizuire. Citește pagina în engleză

perspectiva aiqbenchProduse AI

analiza aiqbench

This research advances electromagnetic navigation systems by applying advanced control theory and dynamic feedback to significantly expand the operational workspace for magnetically guided surgical tools. By optimizing current allocation and leveraging magnetic-field nonlinearity, the study enables stable multi-agent manipulation with drastically reduced power consumption compared to traditional field-centric methods. These system-level improvements represent a critical step toward making complex robotic surgical procedures more scalable and clinically viable.
Sursă care acoperăarXiv
Ce este aceastaLectura unui model asupra articolului și a acoperirii conexe, scrisă pentru aiqbench. Nu sunt cuvintele publicației.

Expanding the Workspace of Electromagnetic Navigation Systems Using Dynamic Feedback for Single- and Multi-agent Control

arXiv3 min de cititArticolul și perspectiva sunt în engleză.

arXiv:2511.18486v2 Announce Type: replace Abstract: Electromagnetic navigation systems (eMNS) enable a number of magnetically guided surgical procedures. A challenge in magnetically manipulating surgical tools is that the effective workspace of an eMNS is often severely constrained by power and thermal limits. We show that system-level control design significantly expands this workspace by reducing the currents needed to achieve a desired motion. We identified five key system approaches that enable this expansion: (i) motion-centric torque/force objectives, (ii) energy-optimal current allocation, (iii) real-time pose estimation, (iv) dynamic feedback, and (v) high-bandwidth eMNS components. As a result, we stabilize a 3D inverted pendulum on an eight-coil OctoMag eMNS with significantly lower currents (0.1-0.2 A vs. 8-14 A), by replacing a field-centric field-alignment strategy with a motion-centric torque/force-based approach. We generalize to multi-agent control by simultaneously stabilizing two inverted pendulums within a shared workspace, exploiting magnetic-field nonlinearity and coil redundancy for independent actuation. A structured analysis compares the electromagnetic workspaces of both paradigms and examines current-allocation strategies that map motion objectives to coil currents. Cross-platform evaluation of the clinically oriented Navion eMNS further demonstrates substantial workspace expansion by maintaining stable balancing at distances up to 50 cm from the coils. The results demonstrate that feedback is a practical path to scalable, efficient, and clinically relevant magnetic manipulation.

Abstract:Electromagnetic navigation systems (eMNS) enable a number of magnetically guided surgical procedures. A challenge in magnetically manipulating surgical tools is that the effective workspace of an eMNS is often severely constrained by power and thermal limits. We show that system-level control design significantly expands this workspace by reducing the currents needed to achieve a desired motion. We identified five key system approaches that enable this expansion: (i) motion-centric torque/force objectives, (ii) energy-optimal current allocation, (iii) real-time pose estimation, (iv) dynamic feedback, and (v) high-bandwidth eMNS components. As a result, we stabilize a 3D inverted pendulum on an eight-coil OctoMag eMNS with significantly lower currents (0.1-0.2 A vs. 8-14 A), by replacing a field-centric field-alignment strategy with a motion-centric torque/force-based approach. We generalize to multi-agent control by simultaneously stabilizing two inverted pendulums within a shared workspace, exploiting magnetic-field nonlinearity and coil redundancy for independent actuation. A structured analysis compares the electromagnetic workspaces of both paradigms and examines current-allocation strategies that map motion objectives to coil currents. Cross-platform evaluation of the clinically oriented Navion eMNS further demonstrates substantial workspace expansion by maintaining stable balancing at distances up to 50 cm from the coils. The results demonstrate that feedback is a practical path to scalable, efficient, and clinically relevant magnetic manipulation.

Robotics (cs.RO); Systems and Control (eess.SY)

arXiv:2511.18486 [cs.RO]

(or arXiv:2511.18486v2 [cs.RO] for this version)

https://doi.org/10.48550/arXiv.2511.18486 Focus to learn more arXiv-issued DOI via DataCite

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Text integral sub licența deschisă a publicației · 303 cuvinte

Subiecte conexe