Sari la conținut

Română · beta. Traducerea a fost făcută automat și este încă în curs de revizuire. Citește pagina în engleză

perspectiva aiqbenchMachine learning

analiza aiqbench

This study evaluates interactive 2D visualization techniques as a sample selection strategy to improve label quality in annotating high-dimensional biomedical time-series data. While the method excels at capturing rare classes and enhancing engagement among expert annotators, it introduces variability that can degrade model performance when trained on individual labels compared to farthest-first traversal approaches. The findings highlight critical trade-offs between annotation efficiency, human expertise levels, and downstream machine learning reliability in specialized domains like infant motility assessment.
Sursă care acoperăarXiv
Ce este aceastaLectura unui model asupra articolului și a acoperirii conexe, scrisă pentru aiqbench. Nu sunt cuvintele publicației.

Evaluating Interactive 2D Visualization as a Sample Selection Strategy for Biomedical Time-Series Data Annotation

arXiv3 min de cititArticolul și perspectiva sunt în engleză.

arXiv:2603.26592v2 Announce Type: replace Abstract: Reliable machine-learning models in biomedical settings depend on accurate labels, yet annotating biomedical time-series data remains challenging. Algorithmic sample selection may support annotation, but evidence from studies involving real human annotators is scarce. Consequently, we compare three sample selection methods for annotation: random sampling (RND), farthest-first traversal (FAFT), and a graphical user interface-based method enabling exploration of complementary 2D visualizations (2DVs) of high-dimensional data. We evaluated the methods across four classification tasks in infant motility assessment (IMA) and speech emotion recognition (SER). Twelve annotators, categorized as experts or non-experts, performed data annotation under a limited annotation budget, and post-annotation experiments were conducted to evaluate the sampling methods. Across all classification tasks, 2DV performed best when aggregating labels across annotators. In IMA, 2DV most effectively captured rare classes, but also exhibited greater annotator-to-annotator label distribution variability resulting from the limited annotation budget, decreasing classification performance when models were trained on individual annotators' labels; in these cases, FAFT excelled. For SER, 2DV outperformed the other methods among expert annotators and matched their performance for non-experts in the individual-annotator setting. A failure risk analysis revealed that RND was the safest choice when annotator count or annotator expertise was uncertain, whereas 2DV had the highest risk due to its greater label distribution variability. Furthermore, post-experiment interviews indicated that 2DV made the annotation task more interesting and enjoyable. Overall, 2DV-based sampling appears promising for biomedical time-series data annotation, particularly when the annotation budget is not highly constrained.

Abstract:Reliable machine-learning models in biomedical settings depend on accurate labels, yet annotating biomedical time-series data remains challenging. Algorithmic sample selection may support annotation, but evidence from studies involving real human annotators is scarce. Consequently, we compare three sample selection methods for annotation: random sampling (RND), farthest-first traversal (FAFT), and a graphical user interface-based method enabling exploration of complementary 2D visualizations (2DVs) of high-dimensional data. We evaluated the methods across four classification tasks in infant motility assessment (IMA) and speech emotion recognition (SER). Twelve annotators, categorized as experts or non-experts, performed data annotation under a limited annotation budget, and post-annotation experiments were conducted to evaluate the sampling methods. Across all classification tasks, 2DV performed best when aggregating labels across annotators. In IMA, 2DV most effectively captured rare classes, but also exhibited greater annotator-to-annotator label distribution variability resulting from the limited annotation budget, decreasing classification performance when models were trained on individual annotators' labels; in these cases, FAFT excelled. For SER, 2DV outperformed the other methods among expert annotators and matched their performance for non-experts in the individual-annotator setting. A failure risk analysis revealed that RND was the safest choice when annotator count or annotator expertise was uncertain, whereas 2DV had the highest risk due to its greater label distribution variability. Furthermore, post-experiment interviews indicated that 2DV made the annotation task more interesting and enjoyable. Overall, 2DV-based sampling appears promising for biomedical time-series data annotation, particularly when the annotation budget is not highly constrained.

Machine Learning (cs.LG); Artificial Intelligence (cs.AI); Human-Computer Interaction (cs.HC)

arXiv:2603.26592 [cs.LG]

(or arXiv:2603.26592v2 [cs.LG] for this version)

https://doi.org/10.48550/arXiv.2603.26592 Focus to learn more arXiv-issued DOI via DataCite

https://doi.org/10.1016/j.compbiomed.2026.111809 Focus to learn more DOI(s) linking to related resources

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Text integral sub licența deschisă a publicației · 350 cuvinte

Subiecte conexe