Sari la conținut

Română · beta. Traducerea a fost făcută automat și este încă în curs de revizuire. Citește pagina în engleză

perspectiva aiqbenchProduse AI

analiza aiqbench

EndoLIFT addresses the critical challenge of intent aliasing in bidirectional robotic control by integrating language instructions with latent-conditioned rectified flow. This approach significantly improves navigation accuracy and reduces erroneous movements when visual cues alone are insufficient to distinguish between advancing and retracting actions. The method demonstrates robust performance across diverse anatomical phantoms, marking a notable advance in vision-language-action policies for medical robotics.
Sursă care acoperăarXiv
Ce este aceastaLectura unui model asupra articolului și a acoperirii conexe, scrisă pentru aiqbench. Nu sunt cuvintele publicației.

EndoLIFT: Language-Disambiguated Latent-Conditioned Rectified Flow for Bidirectional Endoscopic Control

arXiv3 min de cititArticolul și perspectiva sunt în engleză.

arXiv:2608.20478v1 Announce Type: new Abstract: Routine gastrointestinal endoscopy is intrinsically bidirectional: the instrument is advanced to reach target anatomy and later withdrawn or retroflexed for inspection, while an external cue may require earlier reversal. When the requested phase changes before the visual scene does, nearly identical observations can require opposite axial actions. We identify and formalize this ambiguity in bidirectional endoscopic control as intent aliasing. We propose EndoLIFT (Endoscopic Language-Instruction Flow with Trajectory Latents), a vision-language-action policy that combines explicit language-based intent conditioning with a latent-conditioned rectified-flow action expert. The policy receives RGB, a language instruction, and the previous-action state; a 32-D variational trajectory latent stochastically conditions continuous action-chunk generation. Controlled same-observation instruction swaps establish that language selects the axial mode, independently of whether the trajectory latent is present. Relative to the matched model without latent conditioning, EndoLIFT improves navigation-direction accuracy by 11.1 percentage points and reduces wrong-direction advance by 83\%. An architecture-controlled 1-bit mode-flag reference exhibits weaker canonical-anchor switching, while EndoLIFT retains 82.8\% intent-following accuracy across 44 held-out linguistic variants. In closed-loop evaluation, EndoLIFT improves overall success by 30 percentage points over EndoLIFT w/o VTL on both the seen colon phantom and the unseen lung and stomach phantoms, and completes 10/10 ex-vivo porcine-trachea trials. These results separate language-based intent selection from the trajectory latent's contribution to directional correctness and robust retraction.

Abstract:Routine gastrointestinal endoscopy is intrinsically bidirectional: the instrument is advanced to reach target anatomy and later withdrawn or retroflexed for inspection, while an external cue may require earlier reversal. When the requested phase changes before the visual scene does, nearly identical observations can require opposite axial actions. We identify and formalize this ambiguity in bidirectional endoscopic control as intent aliasing. We propose EndoLIFT (Endoscopic Language-Instruction Flow with Trajectory Latents), a vision-language-action policy that combines explicit language-based intent conditioning with a latent-conditioned rectified-flow action expert. The policy receives RGB, a language instruction, and the previous-action state; a 32-D variational trajectory latent stochastically conditions continuous action-chunk generation. Controlled same-observation instruction swaps establish that language selects the axial mode, independently of whether the trajectory latent is present. Relative to the matched model without latent conditioning, EndoLIFT improves navigation-direction accuracy by 11.1 percentage points and reduces wrong-direction advance by 83\%. An architecture-controlled 1-bit mode-flag reference exhibits weaker canonical-anchor switching, while EndoLIFT retains 82.8\% intent-following accuracy across 44 held-out linguistic variants. In closed-loop evaluation, EndoLIFT improves overall success by 30 percentage points over EndoLIFT w/o VTL on both the seen colon phantom and the unseen lung and stomach phantoms, and completes 10/10 ex-vivo porcine-trachea trials. These results separate language-based intent selection from the trajectory latent's contribution to directional correctness and robust retraction.

Robotics (cs.RO)

arXiv:2608.20478 [cs.RO]

(or arXiv:2608.20478v1 [cs.RO] for this version)

https://doi.org/10.48550/arXiv.2608.20478 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Text integral sub licența deschisă a publicației · 310 cuvinte

Subiecte conexe