analiza aiqbench
This study demonstrates a real-time, end-to-end controller for powered prostheses that eliminates the need for manual tuning and explicit intent classification by using temporal convolutional networks. The approach successfully replicated training data scaling for torque and joint flexion across multiple terrains and locomotion modes, including seamless stair transitions. For robotics practitioners, this marks a significant step toward unified, mode-adaptive assistance that reduces the engineering overhead typically associated with subject-specific calibration.
End-to-End Control of a Powered Knee-Ankle Prosthesis Towards Unified, Tuning-Free Assistance
arXiv:2606.07902v1 Announce Type: new Abstract: Powered prostheses conventionally rely on impedance controllers that require extensive manual tuning and explicit mode classification. In this work, we present real-time deployment of an end-to-end prosthesis controller that estimates continuous actuator signals from onboard sensors, eliminating the need for intent classifiers and subject-specific tuning. Temporal Convolutional Networks were trained on a multi-terrain dataset from 18 individuals with transfemoral amputation and deployed in real time across five locomotion modes. Four participants (three able-bodied, one with transfemoral amputation) ambulated across level ground, ramp ascent and descent, and stair ascent and descent. During level walking, the deployed controller reproduced the training-data scaling of peak ankle torque with walking speed (deployed 0.85 Nm/kg per m/s, p = 0.001; training 0.96 Nm/kg per m/s, 95% CI [0.42, 1.50], p = 0.002), after excluding one outlier traced to atypical prosthesis loading. During ramp ascent, the controller scaled knee pre-flexion with grade (deployed 2.92 deg/deg, p = 0.027; training 3.30 deg/deg, 95% CI [1.83, 4.77], p < 0.001). During ramp descent, the controller increased resistive knee torque relative to level walking (deployed +0.16 Nm/kg, p < 0.001; training +0.16 Nm/kg, p = 0.008). Seamless stair transitions were generated for both intact- and prosthetic-side-leading sequences in ascent and descent, despite the training data containing only one limb-leading sequence. These results provide initial evidence towards end-to-end control that can provide unified, mode-adaptive prosthetic assistance without subject-specific tuning.
Abstract:Powered prostheses conventionally rely on impedance controllers that require extensive manual tuning and explicit mode classification. In this work, we present real-time deployment of an end-to-end prosthesis controller that estimates continuous actuator signals from onboard sensors, eliminating the need for intent classifiers and subject-specific tuning. Temporal Convolutional Networks were trained on a multi-terrain dataset from 18 individuals with transfemoral amputation and deployed in real time across five locomotion modes. Four participants (three able-bodied, one with transfemoral amputation) ambulated across level ground, ramp ascent and descent, and stair ascent and descent. During level walking, the deployed controller reproduced the training-data scaling of peak ankle torque with walking speed (deployed 0.85 Nm/kg per m/s, p = 0.001; training 0.96 Nm/kg per m/s, 95% CI [0.42, 1.50], p = 0.002), after excluding one outlier traced to atypical prosthesis loading. During ramp ascent, the controller scaled knee pre-flexion with grade (deployed 2.92 deg/deg, p = 0.027; training 3.30 deg/deg, 95% CI [1.83, 4.77], p < 0.001). During ramp descent, the controller increased resistive knee torque relative to level walking (deployed +0.16 Nm/kg, p < 0.001; training +0.16 Nm/kg, p = 0.008). Seamless stair transitions were generated for both intact- and prosthetic-side-leading sequences in ascent and descent, despite the training data containing only one limb-leading sequence. These results provide initial evidence towards end-to-end control that can provide unified, mode-adaptive prosthetic assistance without subject-specific tuning.
Robotics (cs.RO)
arXiv:2606.07902 [cs.RO]
(or arXiv:2606.07902v1 [cs.RO] for this version)
https://doi.org/10.48550/arXiv.2606.07902 Focus to learn more arXiv-issued DOI via DataCite (pending registration)
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.
Text integral sub licența deschisă a publicației · 322 cuvinte
Subiecte conexe
A Mode-Unified, Continuous, and Biomimetic Control Strategy of a Robotic Lower Limb Prosthesis
arXiv · 15 oct. 2026

[AINews] Reality Checks on AI News (Yegge shuts down Gas Town, Databricks’ +60% Astra cost)
Latent Space · 17 sept. 2026
A Replay-Constrained Simulation Framework for Personalization of Powered Knee--Ankle Prosthesis Controllers
arXiv · 28 iul. 2026

Game-Theoretic Disempowerment: Loss of Control to Agencyless AI
LessWrong · 27 sept. 2026