Sari la conținut

Română · beta. Traducerea a fost făcută automat și este încă în curs de revizuire. Citește pagina în engleză

În afara temei aiqbench

În afara temei aiqbench

Această știre a fost preluată de la o sursă pe care o urmărim, dar nu ține de domeniul AI sau cuantic, așa că nu există o perspectivă aiqbench pentru ea.

Electrostatic Clutch-Based Mechanical Multiplexer with Increased Force Capability

arXiv2 min de cititArticolul și perspectiva sunt în engleză.

arXiv:2501.08469v5 Announce Type: replace Abstract: As robotic systems become increasingly articulated, conventional actuation still dedicates one motor to each degree of freedom (DoF). Mechanical multiplexers address this limitation by allowing a single motor to control multiple outputs through clutches, reducing the number of required motors. However, previous multiplexers have relied on bulky mechanical clutch designs, limiting their development. This study presents an electrostatic capstan clutch-based transmission architecture that enables high-force mechanical multiplexing with independent, simultaneous, and fully actuated control of multiple outputs from a single motor. Our transmission implements four fully-actuated linear outputs, achieving individual output forces of up to 212 N and output speeds of up to 69.5 mm/s. We demonstrate our transmission on a commercial tendon-driven hand, where sequentially allocating system-wide torque capacity to individual outputs increased vertical grip strength by 4.09x and raised horizontal carrying capacity to 111.2 N, the highest reported among five-fingered tendon-driven robotic hands. These results demonstrate that electrostatic clutch-based mechanical multiplexing enables high-force, independent, simultaneous, and fully actuated control while overcoming the limitations of previous mechanical multiplexers.

Abstract:As robotic systems become increasingly articulated, conventional actuation still dedicates one motor to each degree of freedom (DoF). Mechanical multiplexers address this limitation by allowing a single motor to control multiple outputs through clutches, reducing the number of required motors. However, previous multiplexers have relied on bulky mechanical clutch designs, limiting their development. This study presents an electrostatic capstan clutch-based transmission architecture that enables high-force mechanical multiplexing with independent, simultaneous, and fully actuated control of multiple outputs from a single motor. Our transmission implements four fully-actuated linear outputs, achieving individual output forces of up to 212 N and output speeds of up to 69.5 mm/s. We demonstrate our transmission on a commercial tendon-driven hand, where sequentially allocating system-wide torque capacity to individual outputs increased vertical grip strength by 4.09x and raised horizontal carrying capacity to 111.2 N, the highest reported among five-fingered tendon-driven robotic hands. These results demonstrate that electrostatic clutch-based mechanical multiplexing enables high-force, independent, simultaneous, and fully actuated control while overcoming the limitations of previous mechanical multiplexers.

Robotics (cs.RO); Systems and Control (eess.SY)

arXiv:2501.08469 [cs.RO]

(or arXiv:2501.08469v5 [cs.RO] for this version)

https://doi.org/10.48550/arXiv.2501.08469 Focus to learn more arXiv-issued DOI via DataCite

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Text integral sub licența deschisă a publicației · 264 cuvinte

Subiecte conexe