analiza aiqbench
ECGQuest establishes a new literature-grounded benchmark specifically designed to evaluate language models on the contextual knowledge required for electrocardiogram interpretation, addressing gaps in existing medical AI datasets. The study demonstrates that parameter-efficient fine-tuning allows smaller open-source models to compete with large commercial ones, though general-purpose models currently outperform specialized baselines in zero-shot settings. This resource provides a critical infrastructure for advancing reliable, context-aware AI applications in cardiology diagnostics.
ECGQuest: Benchmarking and Fine-Tuning Language Models for Electrocardiography
arXiv:2608.30893v1 Announce Type: new Abstract: Electrocardiogram (ECG) interpretation requires knowledge of cardiology, electrophysiology, clinical diagnosis, ECG waveforms, signal acquisition, and instrumentation. Existing language-model benchmarks, however, primarily assess broad medical knowledge or interpretation of individual ECG signals and images rather than the broader contextual knowledge required for ECG interpretation. We developed ECGQuest, a literature-grounded resource for evaluating and fine-tuning ECG-specific language models. A GPT-4o-based pipeline generated questions from 23 ECG references and Computing in Cardiology proceedings from 2003-2025. The final dataset contains 10,904 unique True/False questions paired with their negated forms (21,808 Q&A pairs). We evaluated three commercial and 20 open-source language models on a held-out test set in a zero-shot setting. Five open-source models with 7-14B parameters were fine-tuned using Low-Rank Adaptation, with BERT and BiomedBERT included as supervised encoder baselines. Generalization was assessed on ECG-related subsets of MedMCQA and MedQA converted to binary True/False questions using official answer keys. Zero-shot accuracy on ECGQuest ranged from 49.5% to 74.4%, with GPT-5 performing best. General-purpose models outperformed medically specialized models, several models showed strong True/False bias, and encoder baselines performed near chance. Fine-tuning improved all open-source models by 6.5-14.1%. Fine-tuned DeepSeek-R1-Distill-Qwen-14B reached 76.3% accuracy, while a five-model voting ensemble reached 78.5%. On MedMCQA and MedQA, fine-tuning mainly benefited weaker or class-biased models and did not consistently improve strong base models. ECGQuest provides a reproducible benchmark for contextual ECG knowledge and shows that parameter-efficient fine-tuning can make smaller language models competitive with substantially larger commercial models.
Abstract:Electrocardiogram (ECG) interpretation requires knowledge of cardiology, electrophysiology, clinical diagnosis, ECG waveforms, signal acquisition, and instrumentation. Existing language-model benchmarks, however, primarily assess broad medical knowledge or interpretation of individual ECG signals and images rather than the broader contextual knowledge required for ECG interpretation. We developed ECGQuest, a literature-grounded resource for evaluating and fine-tuning ECG-specific language models. A GPT-4o-based pipeline generated questions from 23 ECG references and Computing in Cardiology proceedings from 2003-2025. The final dataset contains 10,904 unique True/False questions paired with their negated forms (21,808 Q&A pairs). We evaluated three commercial and 20 open-source language models on a held-out test set in a zero-shot setting. Five open-source models with 7-14B parameters were fine-tuned using Low-Rank Adaptation, with BERT and BiomedBERT included as supervised encoder baselines. Generalization was assessed on ECG-related subsets of MedMCQA and MedQA converted to binary True/False questions using official answer keys. Zero-shot accuracy on ECGQuest ranged from 49.5% to 74.4%, with GPT-5 performing best. General-purpose models outperformed medically specialized models, several models showed strong True/False bias, and encoder baselines performed near chance. Fine-tuning improved all open-source models by 6.5-14.1%. Fine-tuned DeepSeek-R1-Distill-Qwen-14B reached 76.3% accuracy, while a five-model voting ensemble reached 78.5%. On MedMCQA and MedQA, fine-tuning mainly benefited weaker or class-biased models and did not consistently improve strong base models. ECGQuest provides a reproducible benchmark for contextual ECG knowledge and shows that parameter-efficient fine-tuning can make smaller language models competitive with substantially larger commercial models.
Computation and Language (cs.CL); Information Retrieval (cs.IR)
arXiv:2608.30893 [cs.CL]
(or arXiv:2608.30893v1 [cs.CL] for this version)
https://doi.org/10.48550/arXiv.2608.30893 Focus to learn more arXiv-issued DOI via DataCite (pending registration)
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.
Text integral sub licența deschisă a publicației · 337 cuvinte
Subiecte conexe
[AINews] High Taste Testers Ep. 1
Latent Space · 17 oct. 2026
How to Fine-Tune Nemotron 3.5 ASR for Your Language, Domain, or Accent
Hugging Face · 4 iun. 2026
LeRobot v0.6.0: Imagine, Evaluate, Improve
Hugging Face · 7 iul. 2026

Building a Foundation Stack for General-Purpose Robots
IEEE Spectrum · 13 iul. 2026