Sari la conținut

Română · beta. Traducerea a fost făcută automat și este încă în curs de revizuire. Citește pagina în engleză

perspectiva aiqbenchMachine learning

analiza aiqbench

This article introduces ECG-InterpBench, a novel benchmark specifically designed to assess the internal representational quality rather than just predictive accuracy in electrocardiogram foundation models. By utilizing matched-scale sparse autoencoders, it provides a reproducible framework for comparing how well these AI systems can be clinically interpreted and decomposed across different seeds and depths. This work advances machine learning research by shifting focus toward transparency and feature reproducibility within medical imaging models.
Sursă care acoperăarXiv
Ce este aceastaLectura unui model asupra articolului și a acoperirii conexe, scrisă pentru aiqbench. Nu sunt cuvintele publicației.

ECG-InterpBench: Benchmarking the Interpretability of ECG Foundation Models with Matched-Scale Sparse Autoencoders

arXiv3 min de cititArticolul și perspectiva sunt în engleză.

arXiv:2607.27404v1 Announce Type: new Abstract: Existing benchmarks for electrocardiogram foundation models primarily evaluate downstream predictive performance, providing limited insight into whether their internal representations can be faithfully decomposed, clinically interpreted, or reproduced across independent analyses. We introduce ECG-InterpBench, a benchmark designed to systematically evaluate the interpretability of ECG foundation-model representations. ECG-InterpBench uses sparse autoencoders as standardized measurement instruments and matches their capacity across models to enable controlled comparisons. We evaluate six frozen ECG foundation models across five standardized encoder depths, five matched dictionary widths, and three random seeds, producing a 450-cell interpretability atlas comprising 75 exactly matched six-model comparison blocks. The benchmark evaluates complementary dimensions of representation interpretability, including sparse reconstruction fidelity, single-feature accessibility and coverage of 49 clinically meaningful ECG measurements, and cross-seed feature reproducibility. The evaluation further quantifies patient-sampling uncertainty, depth- and seed-dependent variation, and sensitivity to the sparsity parameterization. The benchmark reveals that ECG foundation models exhibit distinct interpretability profiles. A matched replication on MIMIC-IV-ECG confirms that reconstruction fidelity and clinical accessibility identify different leading models. The benchmark is accompanied by executable evaluation code, standardized manifests, cell-level metrics, and reproducibility audits. ECG-InterpBench complements performance-centered ECG benchmarks by providing a capacity-controlled and reproducible framework for comparing ECG foundation models across distinct dimensions of representation interpretability.

Abstract:Existing benchmarks for electrocardiogram foundation models primarily evaluate downstream predictive performance, providing limited insight into whether their internal representations can be faithfully decomposed, clinically interpreted, or reproduced across independent analyses. We introduce ECG-InterpBench, a benchmark designed to systematically evaluate the interpretability of ECG foundation-model representations. ECG-InterpBench uses sparse autoencoders as standardized measurement instruments and matches their capacity across models to enable controlled comparisons. We evaluate six frozen ECG foundation models across five standardized encoder depths, five matched dictionary widths, and three random seeds, producing a 450-cell interpretability atlas comprising 75 exactly matched six-model comparison blocks. The benchmark evaluates complementary dimensions of representation interpretability, including sparse reconstruction fidelity, single-feature accessibility and coverage of 49 clinically meaningful ECG measurements, and cross-seed feature reproducibility. The evaluation further quantifies patient-sampling uncertainty, depth- and seed-dependent variation, and sensitivity to the sparsity parameterization. The benchmark reveals that ECG foundation models exhibit distinct interpretability profiles. A matched replication on MIMIC-IV-ECG confirms that reconstruction fidelity and clinical accessibility identify different leading models. The benchmark is accompanied by executable evaluation code, standardized manifests, cell-level metrics, and reproducibility audits. ECG-InterpBench complements performance-centered ECG benchmarks by providing a capacity-controlled and reproducible framework for comparing ECG foundation models across distinct dimensions of representation interpretability.

Research paper. Includes supplementary material and publicly available source code

Machine Learning (cs.LG); Artificial Intelligence (cs.AI)

arXiv:2607.27404 [cs.LG]

(or arXiv:2607.27404v1 [cs.LG] for this version)

https://doi.org/10.48550/arXiv.2607.27404 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Text integral sub licența deschisă a publicației · 309 cuvinte

Subiecte conexe