Sari la conținut

Română · beta. Traducerea a fost făcută automat și este încă în curs de revizuire. Citește pagina în engleză

În afara temei aiqbench

În afara temei aiqbench

Această știre a fost preluată de la o sursă pe care o urmărim, dar nu ține de domeniul AI sau cuantic, așa că nu există o perspectivă aiqbench pentru ea.

Dual-Platform Precision Measurement of the $3^2D_{5/2}$ to $4^2S_{1/2}$ $g$-Factor Ratio in $^{40}\text{Ca}^+$

arXiv2 min de cititArticolul și perspectiva sunt în engleză.

arXiv:2607.07929v2 Announce Type: replace-cross Abstract: We report precision measurements of the ratio of Land\'e $g$ factors between the $3^2D_{5/2}$ and $4^2S_{1/2}$ states of a single trapped $^{40}\text{Ca}^+$ ion. The measurements are performed in two distinct ion trap apparatus: a cryogenic surface electrode radiofrequency Paul trap and a room-temperature permanent magnet Penning trap. The Penning trap measurements rely on resonant microwave excitation of magnetic sublevels and yield a ratio of $0.599~488~813~3(2)$, which is a more than 40-fold uncertainty reduction compared to previous work. The radiofrequency trap measurements utilize optical electric quadrupole transitions and yield a concurring value of $0.599~488~813(6)$. We estimate that systematic shifts for each system are well below the respective statistical uncertainty.

Abstract:We report precision measurements of the ratio of Landé $g$ factors between the $3^2D_{5/2}$ and $4^2S_{1/2}$ states of a single trapped $^{40}\text{Ca}^+$ ion. The measurements are performed in two distinct ion trap apparatus: a cryogenic surface electrode radiofrequency Paul trap and a room-temperature permanent magnet Penning trap. The Penning trap measurements rely on resonant microwave excitation of magnetic sublevels and yield a ratio of $0.599~488~813~3(2)$, which is a more than 40-fold uncertainty reduction compared to previous work. The radiofrequency trap measurements utilize optical electric quadrupole transitions and yield a concurring value of $0.599~488~813(6)$. We estimate that systematic shifts for each system are well below the respective statistical uncertainty.

Atomic Physics (physics.atom-ph); Quantum Physics (quant-ph)

arXiv:2607.07929 [physics.atom-ph]

(or arXiv:2607.07929v2 [physics.atom-ph] for this version)

https://doi.org/10.48550/arXiv.2607.07929 Focus to learn more arXiv-issued DOI via DataCite

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Text integral sub licența deschisă a publicației · 203 cuvinte

Subiecte conexe