This research reframes Digital Twin degradation not as a fidelity failure but as a detectable signal for identifying cyber-physical attacks in Industrial Control Systems. By leveraging unsupervised learning to monitor temporal inconsistencies between predicted and observed states, the framework achieves high detection reliability without requiring labeled attack data or specific signatures. The approach demonstrates that even under adversarial conditions like sensor degradation or communication delays, analyzing prediction residuals can effectively isolate malicious events from normal operational variance.
Sursă care acoperăarXiv
Ce este aceastaLectura unui model asupra articolului și a acoperirii conexe, scrisă pentru aiqbench. Nu sunt cuvintele publicației.

Digital Twin Degradation: Detecting Cyber Physical Attacks via Temporal Inconsistencies

arXiv3 min de cititArticolul și perspectiva sunt în engleză.

arXiv:2608.16159v1 Announce Type: cross Abstract: Digital Twins (DTs) are increasingly used to monitor and analyze Cyber Physical Systems (CPS). However, in adversarial environments, the fidelity of a DT cannot be assumed. Communication delays, data manipulation, sensor degradation, or partial information loss may cause the DT state to diverge from the physical process it represents. Such divergence creates temporal inconsistencies that may reveal cyber physical attacks. This paper proposes a detection framework that monitors temporal consistency between the physical system and a potentially degraded DT view. A DT predictor is trained exclusively on normal system behavior to model short-term system dynamics. During operation, discrepancies between predicted and observed states are transformed into multi-horizon temporal features capturing the magnitude, persistence, and evolution of prediction residuals. An unsupervised density model characterizes normal consistency patterns, while a sequential change detection mechanism identifies sustained deviations indicative of attacks. The approach is evaluated on three widely used Industrial Control System (ICS) datasets, SWaT, HAI, and BATADAL, under multiple DT degradation scenarios, including time desynchronization and partial observability loss. Results show that temporal inconsistency patterns enable reliable event-level attack detection with bounded false alarm rates and low detection latency. The proposed method achieves up to 98% detection reliability on SWaT and false alarm rates below 2%. Unlike conventional anomaly detection methods, the proposed framework does not require attack signatures or labeled attack data and remains effective even when the DT view is degraded. These results suggest that DT degradation, often treated as a limitation, can instead serve as a useful signal for cyber physical security monitoring.

Abstract:Digital Twins (DTs) are increasingly used to monitor and analyze Cyber Physical Systems (CPS). However, in adversarial environments, the fidelity of a DT cannot be assumed. Communication delays, data manipulation, sensor degradation, or partial information loss may cause the DT state to diverge from the physical process it represents. Such divergence creates temporal inconsistencies that may reveal cyber physical attacks. This paper proposes a detection framework that monitors temporal consistency between the physical system and a potentially degraded DT view. A DT predictor is trained exclusively on normal system behavior to model short-term system dynamics. During operation, discrepancies between predicted and observed states are transformed into multi-horizon temporal features capturing the magnitude, persistence, and evolution of prediction residuals. An unsupervised density model characterizes normal consistency patterns, while a sequential change detection mechanism identifies sustained deviations indicative of attacks. The approach is evaluated on three widely used Industrial Control System (ICS) datasets, SWaT, HAI, and BATADAL, under multiple DT degradation scenarios, including time desynchronization and partial observability loss. Results show that temporal inconsistency patterns enable reliable event-level attack detection with bounded false alarm rates and low detection latency. The proposed method achieves up to 98% detection reliability on SWaT and false alarm rates below 2%. Unlike conventional anomaly detection methods, the proposed framework does not require attack signatures or labeled attack data and remains effective even when the DT view is degraded. These results suggest that DT degradation, often treated as a limitation, can instead serve as a useful signal for cyber physical security monitoring.

Cryptography and Security (cs.CR); Artificial Intelligence (cs.AI); Machine Learning (cs.LG)

arXiv:2608.16159 [cs.CR]

(or arXiv:2608.16159v1 [cs.CR] for this version)

https://doi.org/10.48550/arXiv.2608.16159 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Text integral sub licența deschisă a publicației · 355 cuvinte

Subiecte conexe