analiza aiqbench
Composing insight from the full article — this may take a moment.
Detection Instead of Inversion: T1-T2 Microstructure Quantification With Detection Transformers
arXiv:2611.01790v1 Announce Type: cross Abstract: T1-T2 correlation MRI has strong potential to quantify microstructural compartments without imposing a biological model. Traditionally, full T1-T2 spectra per voxel are reconstructed with an ill-conditioned and time-consuming Inverse Laplace Transform. We propose to view this challenge as an object detection task: A Detection Transformer (DETR) takes 64 TI/TE signals and directly predicts a set of compartments specified by T1, T2, and signal fraction. We achieve a mean average precision mAP@10 of 76.8% on simulated data, outperforming both our previous model design (53.8%) and regularized NNLS (66.1%). We show that our DETR approach outperforms NNLS in almost every setting across compartment count, compartmental signal fraction, and SNR. Reconstruction is orders of magnitude faster than NNLS. The results are fully reproducible from our public code: github.com/SebastianEndtTHI/t1t2-detr
Abstract:T1-T2 correlation MRI has strong potential to quantify microstructural compartments without imposing a biological model. Traditionally, full T1-T2 spectra per voxel are reconstructed with an ill-conditioned and time-consuming Inverse Laplace Transform. We propose to view this challenge as an object detection task: A Detection Transformer (DETR) takes 64 TI/TE signals and directly predicts a set of compartments specified by T1, T2, and signal fraction. We achieve a mean average precision mAP@10 of 76.8% on simulated data, outperforming both our previous model design (53.8%) and regularized NNLS (66.1%). We show that our DETR approach outperforms NNLS in almost every setting across compartment count, compartmental signal fraction, and SNR. Reconstruction is orders of magnitude faster than NNLS. The results are fully reproducible from our public code: this http URL
Computer Vision and Pattern Recognition (cs.CV); Machine Learning (cs.LG); Medical Physics (physics.med-ph)
arXiv:2611.01790 [cs.CV]
(or arXiv:2611.01790v1 [cs.CV] for this version)
https://doi.org/10.48550/arXiv.2611.01790 Focus to learn more arXiv-issued DOI via DataCite (pending registration)
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.
Text integral sub licența deschisă a publicației · 230 cuvinte
Subiecte conexe
Fiber-Resolved Microstructure Quantification from Multi-Shell Diffusion MRI using Detection Transformers
arXiv · 1 oct. 2026
Modelling magnetic material properties with uncertainty-aware neural networks
arXiv · 6 oct. 2026
Modelling magnetic material properties with uncertainty-aware neural networks
arXiv · 12 iun. 2026
A Two-Stage Multi-Modal MRI Framework for Lifespan Brain Age Prediction
arXiv · 18 sept. 2026