Sari la conținut

Română · beta. Traducerea a fost făcută automat și este încă în curs de revizuire. Citește pagina în engleză

perspectiva aiqbenchMachine learning

analiza aiqbench

This research introduces a novel statistical instrument to distinguish between operator misspecification and parameter non-identifiability in hybrid PDE-parameter learning frameworks, addressing a critical blind spot where standard RMSE metrics fail. By demonstrating that this method can reliably detect model failures even when error is masked by observation noise or architectural differences (e.g., MLPs vs. physics-informed networks), it provides essential validation tools for the reliability of AI-driven scientific computing.
Sursă care acoperăarXiv
Ce este aceastaLectura unui model asupra articolului și a acoperirii conexe, scrisă pentru aiqbench. Nu sunt cuvintele publicației.

Detecting and Discriminating Operator Misspecification in Hybrid PDE-Parameter Learning: a Reference-Free Instrument, with Discrimination Bounded In Sample

arXiv3 min de cititArticolul și perspectiva sunt în engleză.

arXiv:2608.16925v1 Announce Type: new Abstract: We build an instrument that reads, from a single fit and with no oracle, whether the operator a hybrid PDE-parameter estimator postulates is wrong-and separates that from a merely unidentifiable parameter. On one self-adjoint parabolic inverse problem, an information-matrix statistic with plug-in scale and per-seed parameter has median 0.19 under correct specification, rejection rate $0.033$ against a pre-registered ceiling of $0.10$, and rises to $224$ and $85$ under two misspecifications, firing in every replicate. On a correctly specified but non-identifiable design it stays mute-$0.050$ at $n=200$, Clopper-Pearson $[0.024, 0.090]$-while a rank statistic collapses to zero at a pre-registered boundary $c_5^*=2.15\times10^{-3}.$ Two readings of one fit therefore separate the two failures across the three designs a deployable test reaches. That separation is the contribution; detection alone is a crowded flank. In sample it is a bound, out of sample a direction. It is needed because the usual accuracy check is blind: the misspecified estimator's in-domain RMSE is $2.7\times 10^{-2}$, below the observation noise for $\sigma\geq 0.05,$ while the coefficient is wrong by $29.7\%$ at zero noise, $31.2\%$ at the loudest. Nor is the failure architectural: a one-parameter curve fit, a bare parameter and multilayer perceptrons of $49$ and $241$ parameters converge to the same pseudo-true, matched in closed form to $0.07\%,$ whereas a physics-informed network, with its composite objective, converges to a disjoint one. We report where the instrument is blind, a pre-registered negative where a neural estimator loses to Tikhonov-regularized inversion at recovery, and the hypothesis under which its guarantee holds but a trained network violates it.

Abstract:We build an instrument that reads, from a single fit and with no oracle, whether the operator a hybrid PDE-parameter estimator postulates is wrong-and separates that from a merely unidentifiable parameter. On one self-adjoint parabolic inverse problem, an information-matrix statistic with plug-in scale and per-seed parameter has median 0.19 under correct specification, rejection rate $0.033$ against a pre-registered ceiling of $0.10$, and rises to $224$ and $85$ under two misspecifications, firing in every replicate. On a correctly specified but non-identifiable design it stays mute-$0.050$ at $n=200$, Clopper-Pearson $[0.024, 0.090]$-while a rank statistic collapses to zero at a pre-registered boundary $c_5^*=2.15\times10^{-3}.$ Two readings of one fit therefore separate the two failures across the three designs a deployable test reaches. That separation is the contribution; detection alone is a crowded flank. In sample it is a bound, out of sample a direction. It is needed because the usual accuracy check is blind: the misspecified estimator's in-domain RMSE is $2.7\times 10^{-2}$, below the observation noise for $\sigma\geq 0.05,$ while the coefficient is wrong by $29.7\%$ at zero noise, $31.2\%$ at the loudest. Nor is the failure architectural: a one-parameter curve fit, a bare parameter and multilayer perceptrons of $49$ and $241$ parameters converge to the same pseudo-true, matched in closed form to $0.07\%,$ whereas a physics-informed network, with its composite objective, converges to a disjoint one. We report where the instrument is blind, a pre-registered negative where a neural estimator loses to Tikhonov-regularized inversion at recovery, and the hypothesis under which its guarantee holds but a trained network violates it.

14 pages, 8 figures. Supplementary material (5 pp.) included as an ancillary file

Machine Learning (cs.LG); Numerical Analysis (math.NA); Methodology (stat.ME)

G.1.8; I.6.4; G.3; I.2.6

arXiv:2608.16925 [cs.LG]

(or arXiv:2608.16925v1 [cs.LG] for this version)

https://doi.org/10.48550/arXiv.2608.16925 Focus to learn more arXiv-issued DOI via DataCite

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Text integral sub licența deschisă a publicației · 371 cuvinte