This paper addresses the critical challenge of safe human-robot interaction in medical imaging by introducing a compliant end-effector that significantly reduces force tracking errors during robotic ultrasound procedures. By leveraging quasi-direct drive actuators for passive compliance and active control, the system enhances image stability and patient safety without sacrificing mechanical performance. The research provides a validated framework for integrating advanced actuation strategies into next-generation autonomous diagnostic tools.
Sursă care acoperăarXiv
Ce este aceastaLectura unui model asupra articolului și a acoperirii conexe, scrisă pentru aiqbench. Nu sunt cuvintele publicației.

Design and Evaluation of a Compliant Quasi Direct Drive End-effector for Safe Robotic Ultrasound Imaging

arXiv3 min de cititArticolul și perspectiva sunt în engleză.

arXiv:2410.03086v2 Announce Type: replace Abstract: Robot-assisted ultrasound scanning promises to advance autonomous and accessible medical imaging. However, ensuring patient safety and compliant human-robot interaction during probe contact poses a significant challenge. Most existing systems either have high mechanical stiffness or trade performance for compliance. This paper presents a novel compliant end-effector designed to mount on robotic arms for safe and accurate robotic ultrasound imaging, using a quasi-direct drive actuator to achieve passive mechanical compliance and precise active force control. To evaluate the end-effector's performance, we developed an ex vivo dynamic motion simulator platform for contact and scanning testing on tissue under simulated movements. The end-effector was evaluated against a UR3e robot arm using conventional force control strategies as a baseline. Single-point contact experiments from 2.5 N to 15 N show that the end-effector reduced force tracking RMS error by 80.1% on average. Trajectory scanning experiments at different speeds showed an average of 68.0% reduction in force tracking error. Statistically significant improvements were observed in four of six quantitative image quality and stability metrics using the end-effector. This work presents a novel approach for designing and evaluating compliant end-effectors, with the goal of improving safety and reliability in robotic ultrasound.

Abstract:Robot-assisted ultrasound scanning promises to advance autonomous and accessible medical imaging. However, ensuring patient safety and compliant human-robot interaction during probe contact poses a significant challenge. Most existing systems either have high mechanical stiffness or trade performance for compliance. This paper presents a novel compliant end-effector designed to mount on robotic arms for safe and accurate robotic ultrasound imaging, using a quasi-direct drive actuator to achieve passive mechanical compliance and precise active force control. To evaluate the end-effector's performance, we developed an ex vivo dynamic motion simulator platform for contact and scanning testing on tissue under simulated movements. The end-effector was evaluated against a UR3e robot arm using conventional force control strategies as a baseline. Single-point contact experiments from 2.5 N to 15 N show that the end-effector reduced force tracking RMS error by 80.1% on average. Trajectory scanning experiments at different speeds showed an average of 68.0% reduction in force tracking error. Statistically significant improvements were observed in four of six quantitative image quality and stability metrics using the end-effector. This work presents a novel approach for designing and evaluating compliant end-effectors, with the goal of improving safety and reliability in robotic ultrasound.

Robotics (cs.RO)

arXiv:2410.03086 [cs.RO]

(or arXiv:2410.03086v2 [cs.RO] for this version)

https://doi.org/10.48550/arXiv.2410.03086 Focus to learn more arXiv-issued DOI via DataCite

IEEE Trans. Med. Robot. Bionics 8(3) (2026) 1383-1395

https://doi.org/10.1109/TMRB.2026.3699216 Focus to learn more DOI(s) linking to related resources

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Text integral sub licența deschisă a publicației · 303 cuvinte

Subiecte conexe