Sari la conținut

Română · beta. Traducerea a fost făcută automat și este încă în curs de revizuire. Citește pagina în engleză

perspectiva aiqbenchMachine learning

analiza aiqbench

This research proposes stabilizing electricity load forecasts by training LSTM and Transformer models to predict load deltas rather than absolute values, effectively addressing target non-stationarity caused by weather and calendar effects. The study demonstrates that this reformulation significantly reduces error rates for short-term predictions while maintaining competitiveness in day-ahead scenarios using deep sequence architectures.
Sursă care acoperăarXiv
Ce este aceastaLectura unui model asupra articolului și a acoperirii conexe, scrisă pentru aiqbench. Nu sunt cuvintele publicației.

Delta-Based Target Reformulation for Short-Term Electricity Load Forecasting Using LSTM and Transformer Models

arXiv3 min de cititArticolul și perspectiva sunt în engleză.

arXiv:2606.17692v1 Announce Type: new Abstract: Accurate short-term electricity load forecasting is critical for the reliable and economic operation of modern power systems, under non-stationarity arising from weather variability, calendar effects, and evolving consumption patterns. While deep learning models such as LSTMs and Transformers show promising performance, most existing studies focus on direct absolute load prediction without explicitly addressing target non-stationarity. Motivated by classical time-series differencing techniques in ARIMA models, this paper investigates a delta-based target reformulation for short-term electricity load forecasting using deep learning. Instead of directly predicting absolute load values, the proposed formulation trains models to predict the change in load between consecutive time steps, with final forecasts reconstructed using the last observed load. This aims to stabilize the learning target and reduce forecasting difficulty. Using multi-year, hourly real-world electricity load data from India, augmented with meteorological variables from the NASA POWER project and calendar features, this study evaluates LSTM and Transformer models under both formulations, benchmarking them against LightGBM. Experiments are conducted for hour-ahead and day-ahead horizons, assessing performance via Mean Absolute Error (MAE) and Mean Absolute Percentage Error (MAPE). Results show that delta-based reformulation consistently improves forecasting accuracy for hour-ahead prediction across all evaluated models, yielding MAPE reductions of over 50% compared to absolute formulations. For day-ahead forecasting, delta targets specifically benefit deep sequence models (LSTM and Transformer), while LightGBM remains competitive under the absolute formulation. These findings indicate that while delta reformulation is a powerful inductive bias for neural networks, its efficacy is model- and horizon-dependent.

Abstract:Accurate short-term electricity load forecasting is critical for the reliable and economic operation of modern power systems, under non-stationarity arising from weather variability, calendar effects, and evolving consumption patterns. While deep learning models such as LSTMs and Transformers show promising performance, most existing studies focus on direct absolute load prediction without explicitly addressing target non-stationarity. Motivated by classical time-series differencing techniques in ARIMA models, this paper investigates a delta-based target reformulation for short-term electricity load forecasting using deep learning. Instead of directly predicting absolute load values, the proposed formulation trains models to predict the change in load between consecutive time steps, with final forecasts reconstructed using the last observed load. This aims to stabilize the learning target and reduce forecasting difficulty. Using multi-year, hourly real-world electricity load data from India, augmented with meteorological variables from the NASA POWER project and calendar features, this study evaluates LSTM and Transformer models under both formulations, benchmarking them against LightGBM. Experiments are conducted for hour-ahead and day-ahead horizons, assessing performance via Mean Absolute Error (MAE) and Mean Absolute Percentage Error (MAPE). Results show that delta-based reformulation consistently improves forecasting accuracy for hour-ahead prediction across all evaluated models, yielding MAPE reductions of over 50% compared to absolute formulations. For day-ahead forecasting, delta targets specifically benefit deep sequence models (LSTM and Transformer), while LightGBM remains competitive under the absolute formulation. These findings indicate that while delta reformulation is a powerful inductive bias for neural networks, its efficacy is model- and horizon-dependent.

Machine Learning (cs.LG)

arXiv:2606.17692 [cs.LG]

(or arXiv:2606.17692v1 [cs.LG] for this version)

https://doi.org/10.48550/arXiv.2606.17692 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Text integral sub licența deschisă a publicației · 339 cuvinte

Subiecte conexe