analiza aiqbench
This research introduces DAMamba-UNet3D, a parameter-efficient architecture that adapts State-Space Models for 3D medical image segmentation by learning dynamic scan patterns. The study demonstrates significant improvements in model efficiency and accuracy over existing Mamba-based segmenters on the BraTS dataset, highlighting the potential of hybrid encoder-decoder designs to overcome computational bottlenecks in volumetric data processing.
DAMamba-UNet3D: A Parameter-Efficient Mamba State Space U-Net with Dynamic Adaptive Scan for 3D Medical Image Segmentation
arXiv:2607.22718v1 Announce Type: cross Abstract: We propose parameter-efficient SSM-based U-Net architectures for 3D medical image segmentation. Convolutional U-Nets afford O(n) local mixing per layer but lack explicit global context; transformers provide global reasoning at O(n^2) cost in sequence length $n$. State-space models (SSMs), such as Mamba, offer $O(n)$ global propagation per block. Yet, existing medical SSM segmenters rely on fixed scan patterns and large parameter budgets. Dynamic Adaptive Scan (DAS), which learns data-dependent reordering before selective scan, has not been applied to medical imaging or extended to 3D volumes. We propose DAMamba-UNet3D, a hybrid encoder-decoder that integrates tri-plane 3D-DAS blocks at encoder stages E2-E4 while retaining convolutions elsewhere (~5.3M parameters). On BraTS 2020 five-fold cross-validation, DAMamba-UNet3D achieves mean Dice 0.815+/-0.013 (full-volume per-case evaluation) at ~13x lower parameter cost than SegMamba (0.824+\-0.014, ~70M). At comparable scale, DAMamba-L (~70M), a wide DAS-native variant with encoder-only DAMamba and a convolutional bottleneck, reaches 0.829+\-0.012, surpassing retrained SegMamba by 0.5pt. Component ablations show that encoder-only DAS placement is critical as bottleneck and decoder SSM blocks lower Dice. Together, the results suggest that learned tri-plane DAS in a hybrid U-Net is competitive with, and under our large-scale design may improve upon, SegMamba's fixed Tri-orientated Mamba (ToM) scanning on BraTS 2020. Code: https://github.com/marafathussain/DAMamba-UNet3D.
Abstract:We propose parameter-efficient SSM-based U-Net architectures for 3D medical image segmentation. Convolutional U-Nets afford O(n) local mixing per layer but lack explicit global context; transformers provide global reasoning at O(n^2) cost in sequence length $n$. State-space models (SSMs), such as Mamba, offer $O(n)$ global propagation per block. Yet, existing medical SSM segmenters rely on fixed scan patterns and large parameter budgets. Dynamic Adaptive Scan (DAS), which learns data-dependent reordering before selective scan, has not been applied to medical imaging or extended to 3D volumes. We propose DAMamba-UNet3D, a hybrid encoder-decoder that integrates tri-plane 3D-DAS blocks at encoder stages E2-E4 while retaining convolutions elsewhere (~5.3M parameters). On BraTS 2020 five-fold cross-validation, DAMamba-UNet3D achieves mean Dice 0.815+/-0.013 (full-volume per-case evaluation) at ~13x lower parameter cost than SegMamba (0.824+\-0.014, ~70M). At comparable scale, DAMamba-L (~70M), a wide DAS-native variant with encoder-only DAMamba and a convolutional bottleneck, reaches 0.829+\-0.012, surpassing retrained SegMamba by 0.5pt. Component ablations show that encoder-only DAS placement is critical as bottleneck and decoder SSM blocks lower Dice. Together, the results suggest that learned tri-plane DAS in a hybrid U-Net is competitive with, and under our large-scale design may improve upon, SegMamba's fixed Tri-orientated Mamba (ToM) scanning on BraTS 2020. Code: this https URL.
Computer Vision and Pattern Recognition (cs.CV); Artificial Intelligence (cs.AI)
arXiv:2607.22718 [cs.CV]
(or arXiv:2607.22718v1 [cs.CV] for this version)
https://doi.org/10.48550/arXiv.2607.22718 Focus to learn more arXiv-issued DOI via DataCite (pending registration)
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.
Text integral sub licența deschisă a publicației · 303 cuvinte
Subiecte conexe

Can we change an AI model’s architecture without retraining it from scratch?
Amazon Science · 12 oct. 2026
[AINews] High Taste Testers Ep. 1
Latent Space · 17 oct. 2026

From CUDA to MLX: How K-Search Brings Decades of Kernel Expertise to Apple Silicon
BAIR Blog · 29 iul. 2026
Observability conditions for neural state-space models with eigenvalues and their roots of unity
arXiv · 9 sept. 2026