Sari la conținut

Română · beta. Traducerea a fost făcută automat și este încă în curs de revizuire. Citește pagina în engleză

perspectiva aiqbenchMachine learning

analiza aiqbench

This research advances flow matching by introducing a cylindrical geodesic path specifically designed to preserve the geometric constraints of quasiperiodic physiological signals, such as phase wrapping and positive amplitude. By replacing standard affine interpolation with this geometry-consistent approach, the method eliminates artifacts in intermediate signal reconstruction while reducing error metrics like Hilbert Transform distance. The work demonstrates that incorporating domain-specific bridge geometry serves as a critical inductive bias for translating cardiovascular waveforms across different wearable sensor locations.
Sursă care acoperăarXiv
Ce este aceastaLectura unui model asupra articolului și a acoperirii conexe, scrisă pentru aiqbench. Nu sunt cuvintele publicației.

Cylindrical Geodesic Flow Matching for Quasiperiodic Physiological Signal Transformation

arXiv3 min de cititArticolul și perspectiva sunt în engleză.

arXiv:2610.08510v1 Announce Type: new Abstract: Paired translation between quasiperiodic physiological waveforms (i.e., recovering a target oscillatory signal from the source) is central to the interpretation of cardiovascular signals derived from wearables placed at different body locations. This source-to-target mapping in these problems carries inherent geometric structure: the phase wraps around the cycle and must be treated as a circular variable, the amplitude remains strictly positive, and the beat-to-beat alignment can drift unpredictably across cycles and subjects. While deep neural networks have been used for phase estimation and complex-valued signal modeling, prior work does not explicitly learn phase transport between paired signals. Consequently, neither endpoint-supervised regression nor the standard affine path used in flow matching accounts for this phase--amplitude structure. We introduce \emph{cylindrical geodesic flow matching} for paired cardiovascular waveform translation. We show that the standard affine path used in flow matching distorts intermediate amplitude and instantaneous frequency when interpolating between quasiperiodic signals; replacing it with a closed-form geodesic on the phase--amplitude cylinder eliminates these artifacts and converts each training pair into dense, geometry-consistent velocity supervision. On zero-shot photoplethysmography and limited-support seismocardiography adaptation benchmarks, our method consistently outperforms interpolation baselines and matches or exceeds direct supervised prediction, reducing Hilbert Transform, $L_2$, and Dynamic Time Warping distance by up to ${\sim}15\%$ over the strongest competing baseline. These results suggest that bridge geometry is a critical inductive bias for flow matching on oscillatory signal translation.

Abstract:Paired translation between quasiperiodic physiological waveforms (i.e., recovering a target oscillatory signal from the source) is central to the interpretation of cardiovascular signals derived from wearables placed at different body locations. This source-to-target mapping in these problems carries inherent geometric structure: the phase wraps around the cycle and must be treated as a circular variable, the amplitude remains strictly positive, and the beat-to-beat alignment can drift unpredictably across cycles and subjects. While deep neural networks have been used for phase estimation and complex-valued signal modeling, prior work does not explicitly learn phase transport between paired signals. Consequently, neither endpoint-supervised regression nor the standard affine path used in flow matching accounts for this phase--amplitude structure. We introduce \emph{cylindrical geodesic flow matching} for paired cardiovascular waveform translation. We show that the standard affine path used in flow matching distorts intermediate amplitude and instantaneous frequency when interpolating between quasiperiodic signals; replacing it with a closed-form geodesic on the phase--amplitude cylinder eliminates these artifacts and converts each training pair into dense, geometry-consistent velocity supervision. On zero-shot photoplethysmography and limited-support seismocardiography adaptation benchmarks, our method consistently outperforms interpolation baselines and matches or exceeds direct supervised prediction, reducing Hilbert Transform, $L_2$, and Dynamic Time Warping distance by up to ${\sim}15\%$ over the strongest competing baseline. These results suggest that bridge geometry is a critical inductive bias for flow matching on oscillatory signal translation.

Artificial Intelligence (cs.AI)

arXiv:2610.08510 [cs.AI]

(or arXiv:2610.08510v1 [cs.AI] for this version)

https://doi.org/10.48550/arXiv.2610.08510 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Text integral sub licența deschisă a publicației · 321 cuvinte

Subiecte conexe