analiza aiqbench
This research introduces CT-$\Delta$Bench, a novel benchmark designed to evaluate vision-language models on their ability to analyze longitudinal changes in 3D medical imaging scans. By moving beyond single-study analysis, the study addresses a critical gap in current foundation models which often fail to capture disease evolution over time. The work also proposes DeltaMed, a baseline model trained specifically for direct paired-CT reasoning, establishing new standards for clinically meaningful temporal comparison.
CT-$\Delta$Bench: A Benchmark for Longitudinal 3D Medical Imaging Difference Reporting with Vision-Language Models
arXiv:2608.11534v2 Announce Type: replace Abstract: In medical imaging, the clinical value of Computed Tomography (CT) lies not only in depicting current disease status, but crucially in enabling longitudinal comparison of serial scans to determine disease evolution, a process that underpins response assessment, recurrence detection, and ongoing patient management. Yet, despite this central role of temporal comparison in clinical decision-making, existing medical foundation models remain largely confined to single-study understanding, leaving temporally grounded cross-examination insufficiently addressed. To address this gap, we study longitudinal imaging difference reporting, a task in which a model takes two temporally separated scans from the same patient and generates a clinically meaningful report describing interval changes between them. We introduce CT-$\Delta$Bench, a dedicated benchmark for this task with patient-level splitting to prevent information leakage. To better evaluate this task beyond surface-level text similarity, we further develop change-aware metrics specifically designed to capture clinically meaningful longitudinal changes, and conduct an independent physician validation to assess the reliability of the synthesized references and event extraction pipeline. We also compare direct paired-CT reasoning with an indirect two-stage pipeline that first generates single-timepoint reports and then performs textual differencing. Finally, we propose DeltaMed, a baseline model for direct paired-CT difference reporting, and train it on the benchmark training set. Together, these contributions lay the groundwork for temporally aware medical foundation models that better reflect real-world longitudinal clinical reasoning.
Abstract:In medical imaging, the clinical value of Computed Tomography (CT) lies not only in depicting current disease status, but crucially in enabling longitudinal comparison of serial scans to determine disease evolution, a process that underpins response assessment, recurrence detection, and ongoing patient management. Yet, despite this central role of temporal comparison in clinical decision-making, existing medical foundation models remain largely confined to single-study understanding, leaving temporally grounded cross-examination insufficiently addressed. To address this gap, we study longitudinal imaging difference reporting, a task in which a model takes two temporally separated scans from the same patient and generates a clinically meaningful report describing interval changes between them. We introduce CT-$\Delta$Bench, a dedicated benchmark for this task with patient-level splitting to prevent information leakage. To better evaluate this task beyond surface-level text similarity, we further develop change-aware metrics specifically designed to capture clinically meaningful longitudinal changes, and conduct an independent physician validation to assess the reliability of the synthesized references and event extraction pipeline. We also compare direct paired-CT reasoning with an indirect two-stage pipeline that first generates single-timepoint reports and then performs textual differencing. Finally, we propose DeltaMed, a baseline model for direct paired-CT difference reporting, and train it on the benchmark training set. Together, these contributions lay the groundwork for temporally aware medical foundation models that better reflect real-world longitudinal clinical reasoning.
Computation and Language (cs.CL); Computer Vision and Pattern Recognition (cs.CV)
arXiv:2608.11534 [cs.CL]
(or arXiv:2608.11534v2 [cs.CL] for this version)
https://doi.org/10.48550/arXiv.2608.11534 Focus to learn more arXiv-issued DOI via DataCite
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.
Text integral sub licența deschisă a publicației · 321 cuvinte
Subiecte conexe

[AINews] Claude Fable/Mythos 5.1: new SOTA model, 75% cache price cut but 70% more output tokens
Latent Space · 2 sept. 2026

[AINews] Opus 5.5 is good at explainer videos
Latent Space · 29 sept. 2026

[AINews] The Future of Latent Space
Latent Space · 25 sept. 2026

Concrete Evaluations to Investigate the OpenAI Model That Hacked Hugging Face
AI Alignment Forum · 3 aug. 2026