analiza aiqbench
CoughSense addresses a critical gap in respiratory AI by moving beyond binary detection to classify five distinct conditions using a lightweight Whisper-tiny backbone. The system's key technical innovations include active-frame QKV attention pooling to mitigate silence-dilution in short audio clips and a dual-encoder fusion strategy that integrates Whisper with the OPERA-CT foundation model. By employing robust techniques for class imbalance and domain shift across four datasets, the model achieves an 82.3% balanced accuracy, demonstrating viability for low-cost smartphone-based screening.
CoughSense: Five-Class Respiratory Disease Classification via Whisper Encoder Fine-Tuning and Dual-Encoder Cross-Attention Fusion with Balanced Contrastive Learning
arXiv:2606.02998v1 Announce Type: new Abstract: Automated cough analysis offers a path to low-cost respiratory screening, but most existing work stops at binary COVID-19 detection. A practical tool needs to tell apart several respiratory conditions from one cough recording on a consumer smartphone. We present CoughSense, a system that sorts cough recordings into five classes. These are healthy, COVID-19, asthma or respiratory condition, bronchitis, and pneumonia. We aggregated 18,301 recordings from four public datasets (Coswara, CoughVID, Virufy, and the West China Hospital Pediatric Cough Dataset) and used the OpenAI Whisper encoder as a pretrained backbone for cough disease classification. The main contribution is active-frame QKV attention pooling, which restricts attention to the first 200 of 1500 encoder tokens. This avoids the silence-dilution problem that arises because a 3-second cough fills only 150 tokens of Whisper's 30-second input window. Other training parts handle the 19 to 1 class imbalance and the four-dataset domain shift. These include WeightedRandomSampler, SpecAugment, Balanced Mixup with forced minority pairing, a supervised contrastive auxiliary loss, FiLM symptom conditioning, and gradient-reversal domain adaptation. A dual-encoder model fuses Whisper with the OPERA-CT respiratory foundation model through cross-attention. CoughSense (Whisper-tiny, 8.6M parameters) reached 82.3 percent balanced accuracy on five-fold cross-validation (macro-F1 of 0.817, AUC of 0.941). It beat an ImageNet-pretrained EfficientNet-B2 by 11.1 points and a ViT trained from scratch by 29.6 points. All five classes passed 74 percent recall and four of five passed 80 percent. The dual-encoder model reached 85.4 percent balanced accuracy. Active-frame pooling is the largest single contributor across all ablation components at 5.1 points, which should help any short-audio task using Whisper as a backbone.
Important: e-prints posted on arXiv are not peer-reviewed by arXiv; they should not be relied upon without context to guide clinical practice or health-related behavior and should not be reported in news media as established information without consulting multiple experts in the field.
Abstract:Automated cough analysis offers a path to low-cost respiratory screening, but most existing work stops at binary COVID-19 detection. A practical tool needs to tell apart several respiratory conditions from one cough recording on a consumer smartphone. We present CoughSense, a system that sorts cough recordings into five classes. These are healthy, COVID-19, asthma or respiratory condition, bronchitis, and pneumonia. We aggregated 18,301 recordings from four public datasets (Coswara, CoughVID, Virufy, and the West China Hospital Pediatric Cough Dataset) and used the OpenAI Whisper encoder as a pretrained backbone for cough disease classification. The main contribution is active-frame QKV attention pooling, which restricts attention to the first 200 of 1500 encoder tokens. This avoids the silence-dilution problem that arises because a 3-second cough fills only 150 tokens of Whisper's 30-second input window. Other training parts handle the 19 to 1 class imbalance and the four-dataset domain shift. These include WeightedRandomSampler, SpecAugment, Balanced Mixup with forced minority pairing, a supervised contrastive auxiliary loss, FiLM symptom conditioning, and gradient-reversal domain adaptation. A dual-encoder model fuses Whisper with the OPERA-CT respiratory foundation model through cross-attention. CoughSense (Whisper-tiny, 8.6M parameters) reached 82.3 percent balanced accuracy on five-fold cross-validation (macro-F1 of 0.817, AUC of 0.941). It beat an ImageNet-pretrained EfficientNet-B2 by 11.1 points and a ViT trained from scratch by 29.6 points. All five classes passed 74 percent recall and four of five passed 80 percent. The dual-encoder model reached 85.4 percent balanced accuracy. Active-frame pooling is the largest single contributor across all ablation components at 5.1 points, which should help any short-audio task using Whisper as a backbone.
Machine Learning (cs.LG); Audio and Speech Processing (eess.AS)
I.2.6; I.5.4; J.3
arXiv:2606.02998 [cs.LG]
(or arXiv:2606.02998v1 [cs.LG] for this version)
https://doi.org/10.48550/arXiv.2606.02998 Focus to learn more arXiv-issued DOI via DataCite (pending registration)
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.
Text integral sub licența deschisă a publicației · 409 cuvinte
Subiecte conexe

A Coding Guide to Google Research’s MSEB: Writing Sound Encoders to the Benchmark Contract and Scoring Them Across Classification, Clustering, Retrieval and Segmentation
MarkTechPost · 27 sept. 2026
AccentCL: Robust Accent Classification with Incremental Expansion
arXiv · 7 oct. 2026
MIFR: A Modality-Invariant and Fair Representation Framework for Skin Disease Classification
arXiv · 20 aug. 2026
Adaptive Conformal Redistribution for Inter-class Transitional Uncertainty in Medical Image Classification
arXiv · 16 sept. 2026