Sari la conținut

Română · beta. Traducerea a fost făcută automat și este încă în curs de revizuire. Citește pagina în engleză

perspectiva aiqbenchProduse AI

analiza aiqbench

This research introduces FreqNO-DPS, a method that corrects the inherent spectral bias of neural operator surrogates by integrating diffusion posterior sampling with a closed-form, frequency-dependent guidance score. By treating surrogate predictions as auxiliary observations, the approach achieves near-zero spectral bias across all frequency bands even with sparse sensor coverage, eliminating the need for denoiser backpropagation. The technique offers a robust framework for high-fidelity PDE solution approximation where fine-scale structural accuracy is critical, validated on 3D elastic wavefield predictions.
Surse care acoperăarXiv, AI Alignment Forum, LessWrong
Ce este aceastaLectura unui model asupra articolului și a acoperirii conexe, scrisă pentru aiqbench. Nu sunt cuvintele publicației.

Correcting Neural Operator Spectral Bias via Diffusion Posterior Sampling with Sparse Observations

arXiv3 min de cititArticolul și perspectiva sunt în engleză.

arXiv:2606.03936v1 Announce Type: new Abstract: Neural operator surrogates (NO) approximate PDE solutions orders of magnitude faster than numerical solvers, but suffer from spectral bias: high-frequency content is systematically attenuated, limiting reliability where fine-scale structure matters. Sparse sensor measurements of the field are often available too, offering pointwise accuracy without spectral distortion but covering only a small fraction of the domain. We address this by treating NO predictions as auxiliary observations in a diffusion posterior sampling framework. Our method, FreqNO-DPS (https://github.com/niccoloperrone/FreqNO-DPS), combines an unconditional score-based diffusion prior, trained on high-fidelity simulations, with diffusion posterior sampling (DPS) conditioned on sparse observations and guided by a frozen neural operator. Naive integration reintroduces the surrogate's spectral bias; we resolve this with a closed-form, spectrally shaped guidance score that weights the surrogate by its frequency-dependent accuracy and needs no denoiser backpropagation. A distribution-free analysis bounds the approximation error across the frequency-diffusion-time plane and shows the guidance's frequency dependence is preserved regardless of distributional assumptions. On 3D elastic wavefield prediction at 5% and 2% sensor coverage, the method reaches near-zero spectral bias across all bands, where both the surrogate and sensor-only DPS show systematic high-frequency attenuation. Isotropic guidance, the natural baseline, improves pointwise accuracy but carries the bias into the posterior nearly intact, confirming that frequency-dependent calibration is essential, not merely beneficial. The framework needs only paired surrogate/reference data and exploits no problem-specific structure beyond the residual's approximate spectral diagonality, verifiable for new surrogates via the coherence diagnostic we provide.

Abstract:Neural operator surrogates (NO) approximate PDE solutions orders of magnitude faster than numerical solvers, but suffer from spectral bias: high-frequency content is systematically attenuated, limiting reliability where fine-scale structure matters. Sparse sensor measurements of the field are often available too, offering pointwise accuracy without spectral distortion but covering only a small fraction of the domain. We address this by treating NO predictions as auxiliary observations in a diffusion posterior sampling framework. Our method, FreqNO-DPS (this https URL), combines an unconditional score-based diffusion prior, trained on high-fidelity simulations, with diffusion posterior sampling (DPS) conditioned on sparse observations and guided by a frozen neural operator. Naive integration reintroduces the surrogate's spectral bias; we resolve this with a closed-form, spectrally shaped guidance score that weights the surrogate by its frequency-dependent accuracy and needs no denoiser backpropagation. A distribution-free analysis bounds the approximation error across the frequency-diffusion-time plane and shows the guidance's frequency dependence is preserved regardless of distributional assumptions. On 3D elastic wavefield prediction at 5% and 2% sensor coverage, the method reaches near-zero spectral bias across all bands, where both the surrogate and sensor-only DPS show systematic high-frequency attenuation. Isotropic guidance, the natural baseline, improves pointwise accuracy but carries the bias into the posterior nearly intact, confirming that frequency-dependent calibration is essential, not merely beneficial. The framework needs only paired surrogate/reference data and exploits no problem-specific structure beyond the residual's approximate spectral diagonality, verifiable for new surrogates via the coherence diagnostic we provide.

Machine Learning (cs.LG); Geophysics (physics.geo-ph)

arXiv:2606.03936 [cs.LG]

(or arXiv:2606.03936v1 [cs.LG] for this version)

https://doi.org/10.48550/arXiv.2606.03936 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Text integral sub licența deschisă a publicației · 337 cuvinte

Subiecte conexe