This research advances sleep staging by fusing single-channel EEG with PPG signals, specifically addressing the limitations of lightweight wearables in short-window scenarios. The study demonstrates that Mamba-enhanced fusion significantly improves light sleep detection across diverse datasets, offering a practical pathway for accessible health monitoring without relying on full-night recordings.
Surse care acoperăarXiv, AI Alignment Forum, LessWrong, The Verge
Ce este aceastaLectura unui model asupra articolului și a acoperirii conexe, scrisă pentru aiqbench. Nu sunt cuvintele publicației.

Combining scEEG and PPG for reliable sleep staging

arXiv3 min de cititArticolul și perspectiva sunt în engleză.

arXiv:2602.15042v2 Announce Type: replace-cross Abstract: Reliable sleep staging remains challenging for lightweight wearable devices such as single-channel electroencephalography (scEEG) or photoplethysmography (PPG). scEEG offers direct measurement of cortical activity and serves as the foundation for sleep staging, yet exhibits limited performance on light sleep stages. PPG provides a low-cost complement that captures autonomic signatures effective for detecting light sleep. However, prior PPG-based methods rely on full night recordings (8 - 10 hours) as input context, which is less practical to provide timely feedback for sleep intervention. In this work, we investigate scEEG-PPG fusion for 4-class sleep staging under short-window (30 s - 30 min) constraints. First, we evaluate the temporal context required for each modality, to better understand the relationship of sleep staging performance with respect to monitoring window. Second, we investigate three fusion strategies: score-level fusion, cross-attention fusion enabling feature-level interactions, and Mamba-enhanced fusion incorporating temporal context modeling. Third, we train and evaluate on the Multi-Ethnic Study of Atherosclerosis (MESA) dataset and perform cross-dataset validation on the Cleveland Family Study (CFS) and the Apnea, Bariatric surgery, and CPAP (ABC) datasets. The Mamba-enhanced fusion achieves the best performance on MESA (Cohen's Kappa $\kappa$ = 0.798, Acc = 86.9%), with particularly notable improvement in light sleep classification (F1-score: 85.63% vs. 77.76%, recall: 82.85% vs. 69.95% for scEEG alone), and generalizes well to CFS and ABC datasets with different populations. These findings suggest that scEEG-PPG fusion is a promising approach for lightweight wearable based sleep monitoring, offering a pathway toward more accessible sleep health assessment. Source code of this project can be found at: https://github.com/DavyWJW/scEEG-PPGFusion

Abstract:Reliable sleep staging remains challenging for lightweight wearable devices such as single-channel electroencephalography (scEEG) or photoplethysmography (PPG). scEEG offers direct measurement of cortical activity and serves as the foundation for sleep staging, yet exhibits limited performance on light sleep stages. PPG provides a low-cost complement that captures autonomic signatures effective for detecting light sleep. However, prior PPG-based methods rely on full night recordings (8 - 10 hours) as input context, which is less practical to provide timely feedback for sleep intervention. In this work, we investigate scEEG-PPG fusion for 4-class sleep staging under short-window (30 s - 30 min) constraints. First, we evaluate the temporal context required for each modality, to better understand the relationship of sleep staging performance with respect to monitoring window. Second, we investigate three fusion strategies: score-level fusion, cross-attention fusion enabling feature-level interactions, and Mamba-enhanced fusion incorporating temporal context modeling. Third, we train and evaluate on the Multi-Ethnic Study of Atherosclerosis (MESA) dataset and perform cross-dataset validation on the Cleveland Family Study (CFS) and the Apnea, Bariatric surgery, and CPAP (ABC) datasets. The Mamba-enhanced fusion achieves the best performance on MESA (Cohen's Kappa $\kappa$ = 0.798, Acc = 86.9%), with particularly notable improvement in light sleep classification (F1-score: 85.63% vs. 77.76%, recall: 82.85% vs. 69.95% for scEEG alone), and generalizes well to CFS and ABC datasets with different populations. These findings suggest that scEEG-PPG fusion is a promising approach for lightweight wearable based sleep monitoring, offering a pathway toward more accessible sleep health assessment. Source code of this project can be found at: this https URL

Signal Processing (eess.SP); Artificial Intelligence (cs.AI)

arXiv:2602.15042 [eess.SP]

(or arXiv:2602.15042v2 [eess.SP] for this version)

https://doi.org/10.48550/arXiv.2602.15042 Focus to learn more arXiv-issued DOI via DataCite

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Text integral sub licența deschisă a publicației · 355 cuvinte