Sari la conținut

Română · beta. Traducerea a fost făcută automat și este încă în curs de revizuire. Citește pagina în engleză

perspectiva aiqbenchCalcul cuantic

analiza aiqbench

This study exposes critical flaws in how Quantum Error Mitigation (QEM) benchmarks are currently evaluated, revealing that temporal hardware drift and arbitrary parameter choices can create a misleading illusion of performance improvement. The authors argue that without rigorous inferential statistics and standardized reporting on these variables, the claimed robustness of NISQ devices may be overstated by up to three times in longitudinal studies. Consequently, the field needs immediate adoption of stricter evaluation protocols involving explicit parameter documentation and drift assessment before QEM can reliably serve as a bridge to fault-tolerant quantum computing.
Surse care acoperăarXiv, Quantum Zeitgeist, Fortune
Ce este aceastaLectura unui model asupra articolului și a acoperirii conexe, scrisă pentru aiqbench. Nu sunt cuvintele publicației.

Claim against Measurement: Statistical Artefacts in Quantum Error Mitigation Benchmarks

arXiv3 min de cititArticolul și perspectiva sunt în engleză.

arXiv:2605.29872v2 Announce Type: replace Abstract: QEM is widely regarded as a plausible bridge from NISQ devices to FTQC. Yet the empirical studies used to assess the effectiveness of QEM techniques on concrete problems have received comparatively little scrutiny with respect to the validity of their conclusions. We systematically review 81 recent QEM papers using an eight-criterion framework covering statistical rigour, reproducibility, and reporting quality. Among the applicable papers, only 15 (25%) use inferential methods, while 25 (42%) report uncertainty only descriptively, without testing whether the claimed effects are statistically supported. To demonstrate the consequences of these omissions, we use ZNE as a representative and widely used case study and identify two compounding sources of artefacts in current QEM benchmarks. First, we observe parameter sensitivity: in a 132-configuration sweep, implicitly assumed choices such as scale factors, extrapolation method, and hardware calibration are not merely incidental but active, with variations changing conclusions from statistically significant improvement to statistically significant degradation. Second, we identify a drift-induced effectiveness illusion: in a 72-hour longitudinal study on real hardware, temporal drift alone can make the same ZNE configuration exhibit an effect size more than three times as large, depending solely on when it is executed, and also drastically reduces the effective number of independent observations. These findings do not imply that QEM methods are intrinsically unsound; rather, they show that current evaluation practice can make mitigation performance appear more robust than the evidence warrants. We therefore propose minimum reporting standards for QEM evaluations, including explicit parameter documentation, robustness checks, longitudinal drift assessment, and inferential statistical testing with effect-size reporting.

Abstract:QEM is widely regarded as a plausible bridge from NISQ devices to FTQC. Yet the empirical studies used to assess the effectiveness of QEM techniques on concrete problems have received comparatively little scrutiny with respect to the validity of their conclusions. We systematically review 81 recent QEM papers using an eight-criterion framework covering statistical rigour, reproducibility, and reporting quality. Among the applicable papers, only 15 (25%) use inferential methods, while 25 (42%) report uncertainty only descriptively, without testing whether the claimed effects are statistically supported. To demonstrate the consequences of these omissions, we use ZNE as a representative and widely used case study and identify two compounding sources of artefacts in current QEM benchmarks. First, we observe parameter sensitivity: in a 132-configuration sweep, implicitly assumed choices such as scale factors, extrapolation method, and hardware calibration are not merely incidental but active, with variations changing conclusions from statistically significant improvement to statistically significant degradation. Second, we identify a drift-induced effectiveness illusion: in a 72-hour longitudinal study on real hardware, temporal drift alone can make the same ZNE configuration exhibit an effect size more than three times as large, depending solely on when it is executed, and also drastically reduces the effective number of independent observations. These findings do not imply that QEM methods are intrinsically unsound; rather, they show that current evaluation practice can make mitigation performance appear more robust than the evidence warrants. We therefore propose minimum reporting standards for QEM evaluations, including explicit parameter documentation, robustness checks, longitudinal drift assessment, and inferential statistical testing with effect-size reporting.

Quantum Physics (quant-ph); Software Engineering (cs.SE)

arXiv:2605.29872 [quant-ph]

(or arXiv:2605.29872v2 [quant-ph] for this version)

https://doi.org/10.48550/arXiv.2605.29872 Focus to learn more arXiv-issued DOI via DataCite

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Text integral sub licența deschisă a publicației · 353 cuvinte

Subiecte conexe