This research presents a robust, unsupervised deep learning framework designed to detect anomalies in pelvic and brain MRIs within AI-driven radiotherapy pipelines. By modeling the distribution of normal medical images using discrete tokens, the system achieves high sensitivity (AUC 0.97) for identifying out-of-distribution data that could compromise clinical workflows. The findings validate unsupervised anomaly detection as a viable automated quality-control layer to ensure safety and reliability in AI-supported healthcare applications.
Sursă care acoperăarXiv
Ce este aceastaLectura unui model asupra articolului și a acoperirii conexe, scrisă pentru aiqbench. Nu sunt cuvintele publicației.

Catching magnetic resonance imaging outliers in artificial intelligence-supported radiotherapy workflows: unsupervised detection and localization of image anomalies using deep learning

arXiv3 min de cititArticolul și perspectiva sunt în engleză.

arXiv:2605.24609v2 Announce Type: replace-cross Abstract: Artificial intelligence is increasingly integrated into radiotherapy workflows, yet such pipelines remain vulnerable to out-of-distribution image data that may introduce unexpected behavior in clinical tasks. Deep learning-based anomaly detection for pelvic magnetic resonance imaging (MRI) remains largely unexplored, and transparent evaluation of its feasibility for full automation is limited. We developed and evaluated a fully automated, unsupervised anomaly-detection framework for pelvic and brain MRI. A two-stage framework was trained on reference images from public datasets: LUND-PROBE for pelvic MRI, and IXI, fastMRI, and fastMRI+ for brain MRI. In the first stage, MRI slices were compressed into discrete tokens; in the second, the distribution of normal tokens was modeled. Anomaly evidence was estimated by combining perceptual image differences with token-surprisal scores based on negative log-likelihood. Automated detection was evaluated on pelvic MRI with synthetic global and real clinical anomalies, and on brain MRI with clinically annotated fastMRI+ abnormalities. Sensitivity, specificity, area under the receiver operating characteristic curve (AUC), and false-positive behavior in held-out normal cases were assessed. The framework achieved robust detection across hidden evaluation cohorts, with AUCs of 0.97 (95% CI, 0.95-0.98) and 0.81 (95% CI, 0.74-0.87) for pelvic and brain MRI, respectively. Heatmap analysis showed strong spatial agreement between detected anomalies and ground-truth locations, supporting localization accuracy and interpretability. These results support the potential of unsupervised anomaly detection as an automated MRI quality-control layer for radiotherapy workflows, with transparent visualization of image regions likely to compromise downstream AI-based tasks.

Abstract:Artificial intelligence is increasingly integrated into radiotherapy workflows, yet such pipelines remain vulnerable to out-of-distribution image data that may introduce unexpected behavior in clinical tasks. Deep learning-based anomaly detection for pelvic magnetic resonance imaging (MRI) remains largely unexplored, and transparent evaluation of its feasibility for full automation is limited. We developed and evaluated a fully automated, unsupervised anomaly-detection framework for pelvic and brain MRI. A two-stage framework was trained on reference images from public datasets: LUND-PROBE for pelvic MRI, and IXI, fastMRI, and fastMRI+ for brain MRI. In the first stage, MRI slices were compressed into discrete tokens; in the second, the distribution of normal tokens was modeled. Anomaly evidence was estimated by combining perceptual image differences with token-surprisal scores based on negative log-likelihood. Automated detection was evaluated on pelvic MRI with synthetic global and real clinical anomalies, and on brain MRI with clinically annotated fastMRI+ abnormalities. Sensitivity, specificity, area under the receiver operating characteristic curve (AUC), and false-positive behavior in held-out normal cases were assessed. The framework achieved robust detection across hidden evaluation cohorts, with AUCs of 0.97 (95% CI, 0.95-0.98) and 0.81 (95% CI, 0.74-0.87) for pelvic and brain MRI, respectively. Heatmap analysis showed strong spatial agreement between detected anomalies and ground-truth locations, supporting localization accuracy and interpretability. These results support the potential of unsupervised anomaly detection as an automated MRI quality-control layer for radiotherapy workflows, with transparent visualization of image regions likely to compromise downstream AI-based tasks.

Medical Physics (physics.med-ph); Artificial Intelligence (cs.AI); Computer Vision and Pattern Recognition (cs.CV)

arXiv:2605.24609 [physics.med-ph]

(or arXiv:2605.24609v2 [physics.med-ph] for this version)

https://doi.org/10.48550/arXiv.2605.24609 Focus to learn more arXiv-issued DOI via DataCite

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.