This research introduces CardioMeta, a multi-task machine learning framework designed to jointly predict diabetes, hypertension, and cardiovascular disease while rigorously addressing label leakage and calibration issues common in healthcare datasets. By leveraging shared encoders with disease-specific heads across NHANES and MIMIC-IV data, the study demonstrates that robust clinical utility relies more on reproducible reliability metrics than inflated accuracy scores. The work highlights critical challenges in external transportability and subgroup fairness when deploying models across heterogeneous electronic health record environments.
Sursă care acoperăarXiv
Ce este aceastaLectura unui model asupra articolului și a acoperirii conexe, scrisă pentru aiqbench. Nu sunt cuvintele publicației.

CardioMeta: Calibrated Multi-Task Prediction of Diabetes, Hypertension, and Cardiovascular Disease Across Population and EHR Data

arXiv3 min de cititArticolul și perspectiva sunt în engleză.

arXiv:2607.15721v2 Announce Type: replace Abstract: Cardiometabolic diseases remain among the most persistent drivers of preventable morbidity because diabetes, hypertension, and cardiovascular disease frequently co-occur and share metabolic, vascular, demographic, and behavioral determinants. Existing machine learning studies for chronic disease prediction often emphasize discrimination on a single dataset, while underreporting label leakage, calibration, temporal robustness, external transportability, and subgroup reliability. This paper presents CardioMeta, a calibrated multi-task framework for joint prediction of diabetes, hypertension, and cardiovascular disease across population survey and electronic health record (EHR) data. The study uses NHANES for population-level model development and temporal validation, and MIMIC-IV for EHR-domain evaluation under substantial distribution shift. To reduce circular label reconstruction, the primary analysis excludes disease-defining variables from the corresponding prediction heads, while a full-clinical feature setting is retained only as sensitivity analysis. CardioMeta combines a shared cardiometabolic encoder with disease-specific gated heads and post-hoc probability calibration. In the leakage-reduced temporal validation setting, the model achieved a macro-AUROC of 0.839, macro-AUPRC of 0.536, macro-F1 of 0.614, and expected calibration error of 0.024, with modest but consistent improvements over strong gradient-boosting and neural tabular baselines. External evaluation on MIMIC-IV showed clear degradation under domain shift, while limited fine-tuning partially recovered performance. The findings indicate that the principal value of multi-task cardiometabolic modeling lies not in inflated accuracy, but in reproducible leakage control, calibrated probabilities, and transparent reliability reporting across heterogeneous healthcare data sources.

Abstract:Cardiometabolic diseases remain among the most persistent drivers of preventable morbidity because diabetes, hypertension, and cardiovascular disease frequently co-occur and share metabolic, vascular, demographic, and behavioral determinants. Existing machine learning studies for chronic disease prediction often emphasize discrimination on a single dataset, while underreporting label leakage, calibration, temporal robustness, external transportability, and subgroup reliability. This paper presents CardioMeta, a calibrated multi-task framework for joint prediction of diabetes, hypertension, and cardiovascular disease across population survey and electronic health record (EHR) data. The study uses NHANES for population-level model development and temporal validation, and MIMIC-IV for EHR-domain evaluation under substantial distribution shift. To reduce circular label reconstruction, the primary analysis excludes disease-defining variables from the corresponding prediction heads, while a full-clinical feature setting is retained only as sensitivity analysis. CardioMeta combines a shared cardiometabolic encoder with disease-specific gated heads and post-hoc probability calibration. In the leakage-reduced temporal validation setting, the model achieved a macro-AUROC of 0.839, macro-AUPRC of 0.536, macro-F1 of 0.614, and expected calibration error of 0.024, with modest but consistent improvements over strong gradient-boosting and neural tabular baselines. External evaluation on MIMIC-IV showed clear degradation under domain shift, while limited fine-tuning partially recovered performance. The findings indicate that the principal value of multi-task cardiometabolic modeling lies not in inflated accuracy, but in reproducible leakage control, calibrated probabilities, and transparent reliability reporting across heterogeneous healthcare data sources.

Machine Learning (cs.LG)

arXiv:2607.15721 [cs.LG]

(or arXiv:2607.15721v2 [cs.LG] for this version)

https://doi.org/10.48550/arXiv.2607.15721 Focus to learn more arXiv-issued DOI via DataCite

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Text integral sub licența deschisă a publicației · 318 cuvinte

Subiecte conexe